Troubleshooting Resources 4–25
Last Failure Reporting
Last failures are automatically displayed on the maintenance terminal (unless disabled via
the FMU) using %LFL formatting. The example below details an occurrence of a Last
Failure report:
In addition, Last Failures are reported to the host error log using Template 01, following a
reboot of the controller. See Table 5–2 for a more detailed explanation of this template.
Events That Allow Controller Operation to Continue
Events that do not cause controller operation to terminate are displayed in one of two
ways:
Spontaneous event log
CLI event reporting
■●●●●●●
3F DAEMON diagnostic failed hard in
non-fault tolerant mode.
DAEMON diagnostic detected critical
hardware component failure; controller
can no longer operate.
Verify that cache module is present. If the
error persists, replace controller.
Table 4–5 Solid OCP Patterns (Sheet 5 of 5)
Pattern OCP
Code
Error Repair Action
%LFL--HSG> --13-JAN-1999 04:39:45 (time not set)-- Last Failure
Code: 20090010
Power On Time: 0.Years, 14.Days, 19.Hours, 58.Minutes, 42.Seconds
Controller Model: HSG80
Serial Number: AA12345678 Hardware Version: 0000(00)
Software Version: V085F(55)
Informational Report
Instance Code: 0102030A
Last Failure Code: 20090010 (No Last Failure Parameters)
Additional information is available in Last Failure Entry: 1.