Compaq HSG80 - StorageWorks RAID Array Controller Especificaciones Pagina 78

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 296
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 77
2–50 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
Replacing DIMMs
Use the following steps in “Removing DIMMs” and “Installing DIMMs” to replace
DIMMs in a cache module. DIMM locations are shown in Figure 2–14 and supported
configurations are shown in Table 2–1.
Figure 2–14. Cache module DIMM locations
CAUTION: ESD can easily damage a cache module or a DIMM. Wear a snug-fitting,
grounded ESD wrist strap.
NOTE: If a DIMM fails, note which DIMM needs replacement based on the diagram displayed on
the console.
CXO6576B
4
2
3
1
Table 2–1 Cache Module Memory Configurations
Memory DIMMs Quantity Location
64 MB 32 MB 2
128 MB 32 MB 4
256 MB 128 MB 2
512 MB 128 MB 4
Vista de pagina 77
1 2 ... 73 74 75 76 77 78 79 80 81 82 83 ... 295 296

Comentarios a estos manuales

Sin comentarios