System Unit
System UnitSystem Unit
System Unit
Dimensions
Dimensions Dimensions
Dimensions
(HxWxD)
14.1-inch,15.0-inch, and
15.4 TFT panel display
support
1.67 x 14.25 x 10.96 in
(42.4 x 362 x 278.5 mm)
Weight
WeightWeight
Weight
With 8-cell std battery
& weight saver
7.515 lb (3.42 kg) with 14.1-inch display
7.731 lb (3.51 kg) with 15.0-inch display
7.786 lb (3.54 kg) with 15.4-inch display
With 12-cell std battery &
diskette drive
8.328 lb (3.79 kg) with 15.4-inch display
With 12-cell std battery &
weight saver
8.040 lb (3.65 kg) with 15.4-inch display
With 12-cell std battery &
garage
8.216 lb (3.73 kg) with 15.4-inch display without
Cage device
8.260 lb (3.75 kg) with 15.4-inch display with
Cage device
NOTE:
NOTE: NOTE:
NOTE:
Height varies depending upon where on the notebook the measurement is made. Weight varies
by configuration and components.
Stand-Alone Power
Stand-Alone PowerStand-Alone Power
Stand-Alone Power
Requirements
RequirementsRequirements
Requirements
*
(*Power Requirements will
vary based on SKU
configuration)
Nominal Operating
Voltage
14.8V (on 8-cell battery)
14.8V (on 12-cell battery)
18.5V (on AC power)
Average Operating Power
(Estimating Batterymark
condition is considered
average operating
condition)
50W
(While system works with Intel Pentium 4 3.2GHz)
Peak Operating Power
(Power user scenario with
CPU operating at 75%
condition)
100W
(While system works with Intel Pentium 4 3.2GHz)
Power in suspend mode
< 500 mW
Power in hibernation mode
< 50 mW
Temperature
TemperatureTemperature
Temperature
Operating
50° to 95° F (10° to 35° C)
Non-operating
-4° to 140° F (-20° to 60° C)
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
Operating
10% to 90% relative humidity, non-condensing
Non-operating
5% to 90% relative humidity, 101.6° F (38.7° C)
maximum wet bulb temperature
Shock
ShockShock
Shock
Operating
40 G, 2 ms, half-sine
Non-operating
240 G, 2 ms, half-sine
Vibration
VibrationVibration
Vibration
Operating
0.5 G, 10 to 500 Hz, 0.5 Oct/Min sweep rate
Non-operating
1.0 G, 10 to 500 Hz, 0.5 Oct/Min sweep rate
Maximum Altitude
Maximum AltitudeMaximum Altitude
Maximum Altitude
(unpressurized)
Operating
0 to 10,000 ft (3,048 m) (14.7 to 10.1 psia)
Non-operating
0 to 30,000 ft (9,144 m) (14.7 to 4.4 psia)
Industry Standard
Industry StandardIndustry Standard
Industry Standard
Blue Angel
No
QuickSpecs
HP Compaq nx9110 and nx9100 Business Notebook
HP Compaq nx9110 and nx9100 Business NotebookHP Compaq nx9110 and nx9100 Business Notebook
HP Compaq nx9110 and nx9100 Business Notebook
Technical Specifications
DA - 11867 Worldwide — Version 16 — April 5, 2005
Page 13