Compaq RAID Array 3000 Controller Shelf Guía de usuario

Busca en linea o descarga Guía de usuario para Redes Compaq RAID Array 3000 Controller Shelf. Compaq RAID Array 3000 Controller Shelf User`s guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 45
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
TruCluster Software Products
Hardware Configuration Technical Update for
StorageWorks RAID Array 3000
January 1999
Product Version: TruCluster Production Server
Software Version 1.5 and TruCluster
Available Server Software Version 1.5
Operating System and Version: Compaq’s DIGITAL UNIX Version
4.0D
This technical update describes how to configure the hardware for the
TruCluster Production Server Software Version 1.5 and TruCluster
Available Server Software Version 1.5 products with a StorageWorks
RAID Array 3000 storage subsystem.
Compaq Computer Corporation
Houston, Texas
Vista de pagina 0
1 2 3 4 5 6 ... 44 45

Indice de contenidos

Pagina 1 - TruCluster Software Products

TruCluster Software ProductsHardware Configuration Technical Update forStorageWorks RAID Array 3000January 1999Product Version: TruCluster Production S

Pagina 2

devices. The included battery backup subsystem is a free-standing UPS.An expansion pedestal option (DS-SWXRA-GD) increases the storagecapacity of the

Pagina 3 - Contents

• The device expansion shelf (DS-SWXRA-GN) for the rackmount versionmust be at revision level B01 or higher.• The DS-BA35X-FA single-ended personality

Pagina 5 - Contents v

2Using the StorageWorks RAID Array3000 in a TruCluster ConfigurationThis chapter describes how to install the hardware for a TruClusterProduction Serve

Pagina 6

• Command Console V2.0 for RAID Array 3000 User’s Guide(AA-RBF2A-TE)—A graphical user interface (GUI) for managingStorageWorks RAID products from a co

Pagina 7 - About This Technical Update

The following sections describe how to install and configure the hardwarefor a TruCluster Production Server Software or TruCluster AvailableServer Soft

Pagina 8

Server configuration using an RA3000 storage subsystem. For TruClusterAvailable Server Software, skip the first step as you do not use MemoryChannel. Al

Pagina 9 - Array 3000 Storage Subsystem

Table 2–1: Configuring TruCluster Hardware for Use with the RA3000(cont.)Step Action Refer to:5 Power up the system and use the showconfig and show dev

Pagina 10

Table 2–1: Configuring TruCluster Hardware for Use with the RA3000(cont.)Step Action Refer to:The preferred method of radial connection toa DWZZH Ultra

Pagina 11

Table 2–2: Installing Cables for RA3000 Radial Configuration with aDWZZH UltraSCSI Hub (cont.)Step Action Refer to:RA3000 controller shelf with active/

Pagina 12

© Compaq Computer Corporation 1999All rights reserved.The following are trademarks of Compaq Computer Corporation: ALL–IN–1, Alpha AXP,AlphaGeneration

Pagina 13

Table 2–3: Installing Cables for RA3000 Configuration Using ExternalTermination and Y Cables (cont.)Step Action Refer to:RA3000 pedestal with active/pa

Pagina 14

Table 2–3: Installing Cables for RA3000 Configuration Using ExternalTermination and Y Cables (cont.)cThe maximum length of the SCSI bus segment, includ

Pagina 15

8. Print the release notes.2.2.2 KZPBA-CB Termination ResistorsThe KZPBA-CB internal termination is disabled by removing thetermination resistors RM1

Pagina 16

Example 2–1: Displaying Configuration on an AlphaServer 4100P00>>> show configDigital Equipment CorporationAlphaServer 4x00Console V5.1-3 Open

Pagina 17

Example 2–2: Displaying Configuration on an AlphaServer 8200 (cont.)5+ MS7CC 5000 0000 ms7cc08+ KFTIA 2020 0000 kftia0C0 Internal PCI connected to kfti

Pagina 18

Example 2–3: Displaying Devices on an AlphaServer 4100 (cont.)dke200.2.0.5.1 DKe200 RZ26 392Adke300.3.0.5.1 DKe300 RZ26L 442Dpolling floppy0 (FLOPPY)

Pagina 19

Example 2–4: Displaying Devices on an AlphaServer 8200 (cont.)dkg300.3.0.2.1 DKG300 RZ26N 0568polling for units on kzpsa1, slot 3, bus 0, hose1...kzps

Pagina 20

Example 2–5: Displaying the pk* Console Environment Variables on anAlphaServer 4100 SystemP00>>>show pk*pka0_disconnect 1pka0_fast 1pka0_host

Pagina 21 - # umount /mnt

• diff—Places the bus in differential modeAs the KZPBA-CB (ISP1040) termination is determined by the presence orabsence of internal temination resisto

Pagina 22 - Commands

2.2.4.2 Setting the KZPBA-CB SCSI IDAfter you determine the console environment variables for the KZPBA-CBson the shared SCSI bus, use the set console

Pagina 23

ContentsAbout This Technical Update1 Introducing the StorageWorks RAID Array 3000 StorageSubsystem1.1StorageWorks RAID Array 3000 General Overview ...

Pagina 24

Figure 2–2: StorageWorks RAID Array 3000 Controller Shelf Front ViewDC PowerSuppliesHSZ22RAIDControllerBlankPanelHost 1I/O ModuleHost 0I/O ModuleDevic

Pagina 25

Figure 2–3: RAID Array 3000 Pedestal Rear ViewUPSHost 0ExternalFaultHost 1Controller 2(top)Controller 1(bottom)ZK-1464U-AID1 OUTknock-outplateUPSH0 IN

Pagina 26 - KZPBA-CB SCSI ID

Figure 2–4: TruCluster Configuration with an RA3000 Controller Shelfwith Active/Passive Failover and a DWZZH-05 UltraSCSI HubHost 0 I/O ModuleHost 1

Pagina 27

Figure 2–5: TruCluster Configuration with an RA3000 Pedestal withActive/Passive Failover and a DWZZH-05 UltraSCSI HubTTTTTT1DS-DWZZH-05KZPBA-CBKZPBA-CB

Pagina 28

Figure 2–6: TruCluster Configuration with an RA3000 Pedestal withActive/Passive Failover and a DWZZH-03 UltraSCSI HubTTTTT1DS-DWZZH-0312KZPBA-CBKZPBA-C

Pagina 29 - 2.2.5 Cabling Illustrations

Figure 2–7: TruCluster Configuration with an RA3000 Controller Shelf withActive/Active or Active/Passive Failover and a DWZZH-05 UltraSCSI HubTTTTTT1DS

Pagina 30 - ZK-1463U-AI

Table 2–5: Hardware Components Used in the Configuration Shown inFigure 2–7Callout Number Description1BN38C HD68 to VHDCI cablea2BN37A VHDCI cableb3 BN

Pagina 31 - ZK-1464U-AI

Figure 2–8: TruCluster Configuration with an RA3000 Pedestal withActive/Active or Active/Passive Failover and a DWZZH-05 UltraSCSI HubTTTTTT1DS-DWZZH-0

Pagina 32 - RAID Array 3000

Figure 2–9: Externally Terminated TruCluster Configuration with anRA3000 Pedestal with Active/Passive FailoverAlphaServerMemberKZPBA-CBSystem 2AlphaSer

Pagina 33 - ZK-1478U-AI

Figure 2–11 shows an externally terminated TruCluster configurationusing an RA3000. In this configuration, because the Host 0 I/O module isdaisy-chained

Pagina 34 - 2 BN37A VHDCI cable

2–5Displaying the pk* Console Environment Variables on anAlphaServer 4100 System ... 2–152–6Displaying Console

Pagina 35 - ZK-1479U-AI

Figure 2–12: Externally Terminated TruCluster Configuration with aMid-bus RA3000 Controller Shelf with Active/Active or Active/PassiveFailoverAlphaServ

Pagina 36

3Reconfiguring the RA3000 Pedestal forthe Expansion Pedestal OptionThe following documentation covers installing the StorageWorks RAIDArray 3000 expans

Pagina 37 - BN37A VHDCI cable

3.2 Reconfiguring the RA3000 Base Pedestal UltraSCSIBusSee the RAID Array 3000 Storage Subsystem Expansion Pedestal OptionInstallation Guide for more i

Pagina 38 - ZK-1481U-AI

Figure 3–1: RA3000 Pedestal Cabled for Split-Bus ConfigurationJ11J16ZK-1467U-AI6. Remove the SCSI bus cable from the J16 backplane connector and thedev

Pagina 39 - ZK-1482U-AI

Figure 3–2: RA3000 Pedestal Cabled for Single-Bus ConfigurationJ11J16ZK-1465U-AI8. Remove the knockout plate above the D1 OUT label on the rear panelof

Pagina 40 - ZK-1484U-AI

Figure 3–3: RA3000 Pedestal SCSI ID RenumberingJ11J16ZK-1466U-AI711. Connect a BN21K (BN21L or BN31G) HD68 cable between the basepedestal D1 OUT conne

Pagina 41 - 3.1 Overview

2–3Installing Cables for RA3000 Configuration Using ExternalTermination and Y Cables ... 2–72–4Hardware Componen

Pagina 43 - ZK-1467U-AI

About This Technical UpdateThis technical update provides important information about using theStorageWorks RAID Array 3000 (RA3000) with the TruClust

Pagina 45 - ZK-1466U-AI

1Introducing the StorageWorks RAIDArray 3000 Storage SubsystemThis technical update to the TruCluster Software Products HardwareConfiguration manual pr

Comentarios a estos manuales

Sin comentarios