Compaq StorageWorks TM RAID Array 3000 Pedestal Storage Subsystem Guía de usuario Pagina 58

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 112
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 57
2-24 RAID Array 3000 Pedestal Storage Subsystem Hardware Users Guide
Compaq Confidential Need to Know Required
Writer: Bob Young Project: RAID Array 3000 Pedestal Storage Subsystem Hardware Users Guide Comments:
Part Number: EK-SMCPO-UG. C01 File Name: c-ch2 RAID Array Controller.doc Last Saved On: 12/4/00 1:51 PM
12 V Supply Voltage
The controller monitors the incoming 12-volt levels and ensures that they are
satisfactory for operation. The acceptable voltage levels are listed in
Table 29.
Table 2-9
Acceptable 12 Volt Levels
State Range Action
Normal 10.80 to 13.80 V Normal operation
Low warning 10.20 to 10.80 V Alarm
High warning 13.80 to 14.40 V Alarm
Low severe Less than 10.20 V Off line
High severe Greater than 14.40 V Off line
Temperature Monitoring
External Temperature
The controller monitors the external operating temperature and ensures that
they are satisfactory for controller operation. The acceptable temperature
levels are listed in Table 2-10.
Table 2-10
Acceptable External Temperature Levels
State Temperature Action
Normal < 106ºF (41ºC) Normal operation
High warning < 106ºF to 126ºF
(41ºC to 52ºC)
Alarm
High severe > 133ºF (52ºC) Off line
Vista de pagina 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 ... 111 112

Comentarios a estos manuales

Sin comentarios