Firmware Update C-15
Before starting LFU, download the update files from the Internet. You will need the
files with the extension .SYS. Copy these files to your local MOP server’s MOP load
area.
Select the device from which firmware will be loaded. The choices are the CD-
ROM, the internal floppy disk, or a network device. In this example, a network
device is selected.
Select the file that has the firmware update, or press Enter to select the default
file. The file options are:
AS1400FW
(default)
SRM console, AlphaBIOS console, and I/O adapter
firmware.
AS1400CP SRM console and AlphaBIOS console firmware only.
AS1400IO I/O adapter firmware only.
In this example the default file, which has both console firmware (AlphaBIOS
and SRM) and I/O adapter firmware, is selected.
Use the LFU list command to determine the revision of firmware in a device
and the most recent revision of that firmware available in the selected file. In
this example, the resident firmware for each console (SRM and AlphaBIOS)
and I/O adapter is at an earlier revision than the firmware in the update file.
Continued on next page