B-12 SMC Installation and Users Guide
B.6 Cable the Terminal Server to the GS160/320
For each console, connect a terminal server port to the local port of
the PCI box.
B.6.1 Make the Cable Connection
Figure B–9 PCI Box Rear Local Port Location
PK-1724-00
1
Make the connection for each console:
1. Attach an H8585–AA connector (12–36054–01) to the local port of the PCI
box (
in Figure B–9).
2. Following the cabling chart in Table B–1, label both ends of a BN25G cable
(17–03212–05) and connect it from the port on the terminal server (
in
Figure B–10 shows the location of the ports) to the H8585–AA connector on
the PCI box.
A partition can have a failover console if the limitation of eight standard I/O
modules in the system is met. The cabling chart in Table B–1 does not
distinguish between primary and failover consoles. For information about
partitioning the system, see the AlphaServer GS80/160/320 Firmware
Reference Manual.