Compaq Portable 486 - Notebook PC Especificaciones Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 88
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
-----------------------------------------------------------------------------
1782 - Disk None Fixed disk drive 1. Run Diagnostics.
Controller controller error 2. Check and/or
Failure replace the power
distribution board.
3. Replace the fixed
disk drive.
-----------------------------------------------------------------------------
Message Beeps Probable Cause Recommended Action
-----------------------------------------------------------------------------
1790 - Disk 0 Error None Fixed disk drive 1. Run Diagnostics.
error or wrong 2. Replace the
drive type drive.
-----------------------------------------------------------------------------
1791 - Disk 1 Error None Fixed disk drive 1. Run Diagnostics.
error or wrong 2. Replace the
drive type drive.
-----------------------------------------------------------------------------
XX000Y ZZ Parity None Parity RAM Run Diagnostics.
Check 2 failure
-----------------------------------------------------------------------------
Audible 1 Short Power on None.
successful
-----------------------------------------------------------------------------
Audible 2 Short Power on None.
successful
-----------------------------------------------------------------------------
(RESUME = None As indicated Press F1 key
"F1" KEY) to continue.
=============================================================================
Cha
p
ter 3.2 Dia
g
nostic Error Codes
Vista de pagina 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 87 88

Comentarios a estos manuales

Sin comentarios