Compaq StorageWorks XP12000 - Disk Array Manual de usuario Pagina 18

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 17
Model
ModelModel
Model
HP StorageWorks XP12000 Disk Array
Number of Disk Drives
Number of Disk DrivesNumber of Disk Drives
Number of Disk Drives
9 -1152 in 1 to 5 cabinets (Disk Control Frame holds 128 disks and the Disk Array Frames hold 256
disks each)
Disk Drives, Interface
Disk Drives, InterfaceDisk Drives, Interface
Disk Drives, Interface
Disk Drives, Capacity and
Spindle Speed
73 GB -
15K rpm
146 GB -
10K rpm
300 GB -
10K rpm
Rotational latency
2.01 ms 2.99 ms 2.99 ms
Average Read/Write Seek
Time
3.8/4.2 ms 4.9/5.4 ms 4.7/5.1 ms
Internal data transfer rate
74.5 to 111.4 MB/sec
57.3 to 99.9
MB/sec
57.3 to 99.9
MB/sec
Capacity
CapacityCapacity
Capacity
576 GB - 332 TB raw
288 GB - 290 TB usable
RAID Level
RAID LevelRAID Level
RAID Level
RAID 1 (2D + 2D, 4D + 4D)
RAID 5 (3D + 1P, 7D + 1P)
RAID 6 (6D + 2P)
Maximum number of
Maximum number ofMaximum number of
Maximum number of
Logical Devices
Logical DevicesLogical Devices
Logical Devices
(LDEVs)
8,192
Cache memory
Cache memoryCache memory
Cache memory
4 GB - 128 GB
Shared memory
Shared memoryShared memory
Shared memory
1 GB to 6 GB
Battery backup time
Battery backup timeBattery backup time
Battery backup time
48 hours minimum
Operating Systems
Operating SystemsOperating Systems
Operating Systems
HP-UX, Tru64, Open VMS, NonStop, Solaris(8,9), AIX(5.1, 5.2), AIX(4.3.3, 5L), Windows (2000, 2003),
NetWare(6.0), IRIX64(6.5.16), Linux(3.0), Mainframe
Host Interface
Host InterfaceHost Interface
Host Interface
Fibre Channel, ESCON, FICON
Host Ports
Host PortsHost Ports
Host Ports
8 to 128 by increments of 8/16/32
Drive Interface
Drive InterfaceDrive Interface
Drive Interface
Dual ported 2 GBPS Fibre Channel Arbitrated Loop (FC-AL)
Regulatory Approvals
Regulatory ApprovalsRegulatory Approvals
Regulatory Approvals
This product meets all applicable safety and regulatory specifications
Physical Dimensions -
Physical Dimensions -Physical Dimensions -
Physical Dimensions -
Disk control frame
Disk control frameDisk control frame
Disk control frame
(DKC)
Width x Depth x Height
30.8 x 36.4 x 73.2 in (78.2 x 92.5 x 186.0 cm)
Max Weight
1930 lb (877 kg)
Physical Dimensions -
Physical Dimensions -Physical Dimensions -
Physical Dimensions -
Disk array frame
Disk array frameDisk array frame
Disk array frame
(DKU)
Width x Depth x Height
25.6 x 36.4 x 73.2 in (65.0 x 92.5 x 186.0 cm)
Max Weight
1630 lb (741 kg)
Shipping Dimensions -
Shipping Dimensions -Shipping Dimensions -
Shipping Dimensions -
Disk control frame
Disk control frameDisk control frame
Disk control frame
(DKC)
Width x Depth x Height
37.4 x 43.7 x 79.9 in (95.0 x 111.0 x 203.0 cm)
Max Weight
2180 lb (988.8 kg)
Shipping Dimensions -
Shipping Dimensions -Shipping Dimensions -
Shipping Dimensions -
Disk array frame
Disk array frameDisk array frame
Disk array frame
(DKU)
Width x Depth x Height
37.4 x 43.7 x 79.9 in (95.0 x 111.0 x 203.0 cm)
Max Weight
1880 lb (852.7 kg)
Heat Dissipation and
Heat Dissipation andHeat Dissipation and
Heat Dissipation and
Power Consumption
Power ConsumptionPower Consumption
Power Consumption
Specifications
SpecificationsSpecifications
Specifications
Parameter
ParameterParameter
Parameter
DKC
DKCDKC
DKC
Each DKU
Each DKUEach DKU
Each DKU
Full Array
Full ArrayFull Array
Full Array
(4 DKUs and 1 DKC)
Power consumption (kVA)
8.45 7.50
38.45
Heat dissipation (kW)
8.02 6.75
35.02
BTUs per hour
27370 23036
119514
Kcal per hour
6897 5805
30117
QuickSpecs
HP StorageWorks XP12000 Disk Array
HP StorageWorks XP12000 Disk ArrayHP StorageWorks XP12000 Disk Array
HP StorageWorks XP12000 Disk Array
Technical Specifications
DA - 12072 Worldwide — Version 4 — May 16, 2005
Page 18
Vista de pagina 17
1 2 ... 13 14 15 16 17 18 19 20 21 22

Comentarios a estos manuales

Sin comentarios