Compaq StorageWorks TM RAID Array 3000 Pedestal Storage Subsystem Manual de servicio Pagina 160

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 422
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 159
The configuration that is shown in Figure 6–8 is a NSPOF configuration,
but is not a recommended cluster configuration because of the performance
loss during failure conditions. If a switch or cable failure causes a failover to
the other switch, access to the storage units has to be moved to the other
controller, and that takes time. In the configurations shown in Figure 6–6
and Figure 6–7, the failure would cause access to the storage unit to shift
to the other port of the same controller. This is faster than a change of
controllers, providing better overall performance.
______________________ Note _______________________
If you have a configuration like the one that is shown in
Figure 6–8, change the switch to HSG80 cabling to match the
configurations that are shown in Figure 6–6 or Figure 6–7.
The single-system configuration that is shown in Figure 6–9 is also a
configuration that we do not recommend.
6–14 Using Fibre Channel Storage
Vista de pagina 159
1 2 ... 155 156 157 158 159 160 161 162 163 164 165 ... 421 422

Comentarios a estos manuales

Sin comentarios