Compaq StorageWorks TM RAID Array 3000 Pedestal Storage Subsystem Manual de servicio Pagina 86

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 422
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 85
Table 3–4: Hardware Components Shown in Figure 3–5 Through Figure 3–8
Callout Number
Description
1
BN38C cable
a
2
BN37A cable
b
3
H8861-AA VHDCI trilink connector
4
H8863-AA VHDCI terminator
b
a
The maximum length of the BN38C (or BN38D) cable on one SCSI bus segment must not exceed 25
meters (82 feet).
b
The maximum combined length of the BN37A cables must not exceed 25 meters (82 feet).
Figure 3–6 shows a two-member TruCluster Server configuration with a
radially connected dual-redundant HSZ80 RAID array controller configured
for transparent failover.
Figure 3–6: Shared SCSI Bus with HSZ80 Configured for Transparent
Failover
KZPBA-CB (ID 7)
Network
Memory
Channel
Interface
Memory Channel
KZPBA-CB (ID 6)
Memory Channel
Member
System
2
Member
System
1
StorageWorks
RAID Array 8000
HSZ80
HSZ80
Controller A
Controller B
DS-DWZZH-03
T
T
T
T
2
3
1
4
1
3
Port 1
Port 2
2
Port 1
Port 2
T
T
ZK-1600U-AI
Table 3–4 lists the components that are used to create the cluster that is
shown in Figure 3–6.
3–22 Shared SCSI Bus Requirements and Configurations Using UltraSCSI Hardware
Vista de pagina 85
1 2 ... 81 82 83 84 85 86 87 88 89 90 91 ... 421 422

Comentarios a estos manuales

Sin comentarios