Operation and Reference Guide
Second Edition (October 1999)
Part Number 341252-002
Compaq Computer Corporation
Vista de pagina 0
1 2 3 4 5 6 ... 90 91

Indice de contenidos

Pagina 1 - Compaq Computer Corporation

Operation and Reference GuideSecond Edition (October 1999)Part Number 341252-002Compaq Computer Corporation

Pagina 2

x Compaq 2000 Series UPS Operation and Reference GuideWARNING: The 2000 Series UPS models weigh between 79 and 97 lb(36 to 44 kg) when fully assemb

Pagina 3 - Contents

About This Guide xi Technical support registration number (if applicable) Product serial number(s) Product model name(s) and number(s) Appli

Pagina 4 - Chapter 5

Chapter 1OverviewThis chapter contains information on the following topics: Compaq 2000 Series Uninterruptible Power System (UPS) models 2000 Seri

Pagina 5 - Appendix B

1-2 Compaq 2000 Series UPS Operation and Reference GuideCompaq 2000 Series UPS ModelsThe 2000 Series includes the following UPS models: Table 1-1 20

Pagina 6 - Appendix C

Overview 1-3Rear PanelsThe 2000 Series UPS models feature the following rear panel configurations:91 2 34567810Figure 1-2. Rear panel of T2000 and

Pagina 7 - About This Guide

1-4 Compaq 2000 Series UPS Operation and Reference Guide10AMP1 2345678910 Figure 1-3. Rear panel of T2400hCommunications port Network Transient Pro

Pagina 8 - Symbols on Equipment

Overview 1-510AMP1 2345678910 Figure 1-4. Rear panel of T2400h-NACommunications port Network Transient ProtectorBattery connector Load segment 3IEC

Pagina 9

1-6 Compaq 2000 Series UPS Operation and Reference Guide Communications PortThe 2000 Series UPS models include a communications port that allows the

Pagina 10 - Getting Help

Overview 1-7This sequence might include: Saving work-in-progress throughout the network. Powering down non-critical devices, to extend the batte

Pagina 11 - Compaq Authorized Reseller

1-8 Compaq 2000 Series UPS Operation and Reference GuideCompaq Scalable UPS CardThe Scalable UPS Card makes up to three UPS units appear as a single

Pagina 12 - Overview

NoticeThe information in this publication is subject to change without notice.COMPAQ COMPUTER CORPORATION SHALL NOT BE LIABLE FOR TECHNICAL OREDITORIA

Pagina 13 - Compaq 2000 Series UPS Models

Overview 1-9Warranties$25,000 Computer Load Protection GuaranteeTo back up the wide range of features offered with the UPS, Compaq providesa three-y

Pagina 14 - Rear Panels

Chapter 2InstallationThis chapter provides information on the following topics: Installation requirements Procedures to complete before starting t

Pagina 15

2-2 Compaq 2000 Series UPS Operation and Reference GuideInstallation RequirementsThis section lists items needed to install the Compaq 2000 Series U

Pagina 16 - Overview 1-5

Installation 2-3All models ship with a computer interface cable. The computer interface cableis not needed for normal operation. If power management

Pagina 17 - Power Management Software

2-4 Compaq 2000 Series UPS Operation and Reference GuideCOMM. PORTM. PORT Figure 2-1. Connecting the external battery moduleConnecting to the Commu

Pagina 18 - Hardware Option Cards

Installation 2-5COMM PORTCOMM. PO Figure 2-2. Connecting the UPS/computer interface cableConnecting the Network Transient ProtectorThe 2000 Series

Pagina 19 - Network Transient Protector

2-6 Compaq 2000 Series UPS Operation and Reference GuideStarting the UPSStarting the UPS for the first time requires the following procedures: Che

Pagina 20 - Warranties

Installation 2-7Connecting the UPS to Utility Power Connect the UPS to a grounded utility power outlet.WARNING: To reduce the risk of electric shoc

Pagina 21 - Installation

2-8 Compaq 2000 Series UPS Operation and Reference Guide12345678910111213141516171819Figure 2-5. The front panel LED display and controlsSymbol–AC

Pagina 22 - Installation Requirements

Installation 2-9Check the front panel LED display: LED 16 (ON LED, ) should be off, indicating that no power isavailable at the UPS output recept

Pagina 23 - Before Starting the UPS

ContentsAbout This GuideText Conventions...viiSymb

Pagina 24

2-10 Compaq 2000 Series UPS Operation and Reference GuidePlacing the UPS in Operate modePress and hold the ON button ( ) until the LED 16 ( , ON LED

Pagina 25 - Installation 2-5

Chapter 3OperationThis chapter contains information on: Precautions to be observed when using the UPS UPS modes of operation Front panel control

Pagina 26 - ■ Powering up the UPS

3-2 Compaq 2000 Series UPS Operation and Reference GuidePrecautionsObserve these precautions when using the Compaq 2000 Series UPS models.WARNING:

Pagina 27 - Powering up the UPS

Operation 3-3 Sleep Mode By default, the Sleep mode is disabled.When the Sleep mode is disabled: If the batteries have been fully discharged, powe

Pagina 28

3-4 Compaq 2000 Series UPS Operation and Reference GuideThe front panel includes the following controls and indicators:12345678910111213141516171819

Pagina 29 - Completing the Installation

Operation 3-5Front Panel IndicatorsThe front panel LED display colors indicate the UPS status: Green LEDs indicate normal conditions. Red LEDs p

Pagina 30 - STANDBY button

3-6 Compaq 2000 Series UPS Operation and Reference GuideSite Wiring Fault (LED 5) Table 3-2Site Wiring Fault LED LED Color Meaning 5 Red No grou

Pagina 31 - Operation

Operation 3-7Load Level (LEDs 11-14) Table 3-5Load Level LEDs LED Color Meaning 11 Red Load on the UPS exceeds the maximum power available. 12

Pagina 32 - Modes of Operation

3-8 Compaq 2000 Series UPS Operation and Reference Guide Overcurrent ProtectionOvercurrent protection is provided using the resettable circuit break

Pagina 33 - Front Panel Controls

Operation 3-9231Figure 3-2. Operate mode controlsON LEDON buttonSTANDBY button Returning to Standby ModeWhen the UPS is in Operate mode (LED 16, ,

Pagina 34

iv Compaq 2000 Series UPS Operation and Reference GuideInstallationcontinuedBefore Starting the UPS...

Pagina 35 - Front Panel Indicators

3-10 Compaq 2000 Series UPS Operation and Reference Guide21Figure 3-3. Standby mode controlsON LEDSTANDBY buttonIMPORTANT: While in Standby mod

Pagina 36

Operation 3-11Initiating a Self-testTo initiate a self-test, press the TEST/ALARM RESET button ( ) and holdfor three seconds. The UPS acknowledges c

Pagina 37 - Operation 3-7

3-12 Compaq 2000 Series UPS Operation and Reference GuideAudio AlarmThe UPS may sound an audio alarm to warn the user that an alarm conditionexists.

Pagina 38 - Overcurrent Protection

Operation 3-13Silencing an Audio AlarmTo silence an audio alarm, press the TEST/ALARM RESET button.1 Figure 3-5. TEST/ALARM RESET buttonTEST/ALARM

Pagina 39 - Returning to Standby Mode

Chapter 4ConfigurationThis chapter contains information on the following topics: Placing the UPS in Configure mode Configuration parameters and th

Pagina 40

4-2 Compaq 2000 Series UPS Operation and Reference GuidePlacing the UPS in Configure ModeThe Compaq 2000 Series UPS models can enter the Configure m

Pagina 41 - Initiating a Self-test

Configuration 4-3Configuration Parametersand their LED IndicatorsIn the Configure mode, the front panel LEDs 1 to 15 are assigned to elevenconfigura

Pagina 42 - Audio Alarm

4-4 Compaq 2000 Series UPS Operation and Reference GuideTable 4-1Configuration Parameters/LED IndicatorsParameter(LED)ParameterNameLED 16StatusExpla

Pagina 43 - Silencing an Audio Alarm

Configuration 4-5Table 4-1Configuration Parameters/LED Indicators continuedParameter(LED)ParameterNameLED 16StatusExplanation8 AC Input Failure On(d

Pagina 44 - Configuration

4-6 Compaq 2000 Series UPS Operation and Reference GuideChanging Configuration ParametersThe Configure mode can be entered from the Operate or Stand

Pagina 45

About This Guide vBattery MaintenancecontinuedReplacing an External Battery Module...

Pagina 46 - Configuration 4-3

Configuration 4-7NOTE: For nominal voltage configuration parameters 1, 2, 3, and 10—selecting an ONvalue for any one parameter automatically sets t

Pagina 47 - Table 4-1

4-8 Compaq 2000 Series UPS Operation and Reference GuideFigure 4-4. Optimal—Utility voltage fluctuating within the UPS operatingrangeOperating Rang

Pagina 48 - Configuration 4-5

Configuration 4-9 If the utility voltage frequently varies outside the UPS operating range(see Fig 4-6), consider changing from normal to extended

Pagina 49

Chapter 5Battery MaintenanceThis chapter contains information on the following topics: Precautions to be observed when maintaining or replacing exte

Pagina 50 - Optimizing Battery Life

5-2 Compaq 2000 Series UPS Operation and Reference GuidePrecautionsWARNING: There is a risk of personal injury from the hazardous energy levelsasso

Pagina 51

Battery Maintenance 5-3IMPORTANT: Before handling a tower UPS, make sure that the UPS is on a flat, stablesurface.Charging BatteriesThe Compaq 2000

Pagina 52 - Table 4-3

5-4 Compaq 2000 Series UPS Operation and Reference GuideVerify that battery module replacement is required by initiating a UPS self-test. If LED 10

Pagina 53 - Battery Maintenance

Battery Maintenance 5-5Replacing an External Battery ModuleThere are two options for replacing a UPS external battery module: Powering off the UPS

Pagina 54

5-6 Compaq 2000 Series UPS Operation and Reference GuideStep 2: Removing the External Battery ModuleUse this procedure to remove the external batter

Pagina 55 - When to Replace Batteries

Battery Maintenance 5-7Step 3: Installing a New Battery ModuleConnect the battery cables from the new external battery module to the batteryreceptac

Pagina 56 - Pre-Failure Battery Warranty

vi Compaq 2000 Series UPS Operation and Reference GuideAppendix CSpecificationsPhysical Specifications ...

Pagina 57 - Step 1: Preparing the UPS

5-8 Compaq 2000 Series UPS Operation and Reference GuideStep 4: Testing a New Battery ModuleAfter installing the new battery module, press the TEST/

Pagina 58 - COMM. PORT

Battery Maintenance 5-9Care and Storage of BatteriesTo maximize battery life: Minimize the amount of time the UPS is using battery power. MatchUPS

Pagina 59 - Battery Maintenance 5-7

Chapter 6TroubleshootingThis chapter provides information on the following topics: Troubleshooting problems that occur during UPS start Troublesho

Pagina 60

6-2 Compaq 2000 Series UPS Operation and Reference GuideTroubleshooting During StartIf problems occur when starting the Compaq 2000 Series UPS model

Pagina 61 - Care and Storage of Batteries

Troubleshooting 6-3Troubleshooting After StartFor problems that occur after the UPS has gone through the startup self-testsequence, these suggested

Pagina 62 - Troubleshooting

6-4 Compaq 2000 Series UPS Operation and Reference GuideTable 6-2Troubleshooting Guide (After Start) continuedSymptom Possible Cause Suggested Actio

Pagina 63 - Troubleshooting During Start

Troubleshooting 6-5Table 6-2Troubleshooting Guide (After Start) continuedSymptom Possible Cause Suggested ActionLED 10 isflashing red;audio alarmcan

Pagina 64 - Troubleshooting After Start

Appendix ARegulatory Compliance NoticesFederal CommunicationsCommission NoticePart 15 of the Federal Communications Commission (FCC) Rules andRegulati

Pagina 65 - Table 6-2

A-2 Compaq 2000 Series UPS Operation and Reference GuideClass A EquipmentThis equipment has been tested and found to comply with the limits for a Cl

Pagina 66 - Repairing the UPS

Regulatory Compliance Notices A-3Declaration of Conformity for Products Markedwith the FCC logo - United States OnlyThis device complies with Part 1

Pagina 67 - Regulatory Compliance Notices

About This GuideThis guide is designed to be used as step-by-step instructions for installationand as a reference for operation, troubleshooting, and

Pagina 68 - Class B Equipment

A-4 Compaq 2000 Series UPS Operation and Reference GuideCanadian Notice (Avis Canadien)Class A EquipmentThis Class A digital apparatus meets all req

Pagina 69 - Modifications

Regulatory Compliance Notices A-5Japanese NoticeJuly 14 versionTaiwanese Notice

Pagina 70 - European Union Notice

A-6 Compaq 2000 Series UPS Operation and Reference Guide Battery Replacement Notice Your UPS is provided with a Sealed Lead Acid battery pack. There

Pagina 71 - Taiwanese Notice

Appendix BElectrostatic DischargeTo prevent damaging the system, be aware of the precautions you need tofollow when setting up the system or handling

Pagina 72 - Battery Replacement Notice

B-2 Compaq 2000 Series UPS Operation and Reference GuideGrounding MethodsThere are several methods for grounding. Use one or more of the followingme

Pagina 73 - Electrostatic Discharge

Appendix CSpecificationsThis appendix provides specifications that apply to Compaq 2000 Series UPSmodels: Physical specifications Input specificat

Pagina 74 - Grounding Methods

C-2 Compaq 2000 Series UPS Operation and Reference GuidePhysical SpecificationsTable C-1Physical Specifications - Models T2000 and T2000jDevice Feat

Pagina 75 - Specifications

Specifications C-3Input SpecificationsTable C-3Input Specifications – Per ModelUPS Model Utility VoltageFrequency (Hz)Nominal UtilityVoltage (VAC)Po

Pagina 76 - Physical Specifications

C-4 Compaq 2000 Series UPS Operation and Reference GuideOutput SpecificationsTable C-4Output Specifications – Per ModelUPS Model Nominal PowerRating

Pagina 77 - Input Specifications

Specifications C-5Table C-5Output Specifications – 2000 Series UPS ModelsCharacteristics Utility Voltage (VAC) Nominal Output Voltage (VAC)Voltage 1

Pagina 78 - Output Specifications

viii Compaq 2000 Series UPS Operation and Reference GuideSymbols in TextThese symbols may be found in the text of this guide. They have the followin

Pagina 79 - Table C-5

C-6 Compaq 2000 Series UPS Operation and Reference GuideOvercurrent Protection Table C-6Overcurrent Protection – Per Model UPS Model Input Protect

Pagina 80 - Battery Specifications

Specifications C-7Battery RuntimeTable C-8Estimated Battery Runtime (Minutes)Load (VA) 2000 Models 2400 Models450 58 108500 51 97600 36 81700 30 628

Pagina 81 - Battery Runtime

C-8 Compaq 2000 Series UPS Operation and Reference GuideEnvironmental SpecificationsTable C-9Environmental Specifications – 2000 Series UPS ModelsFe

Pagina 82 - Environmental Specifications

IndexNumbers and Symbols2000 Series UPS SeeUninterruptible Power System2000 SeriesAAC Input Failuredisabling audio alarm 4-5enabling audio alarm

Pagina 83 - Numbers and Symbols

2 Compaq 2000 Series UPS Operation and Reference Guidenewrecommendation against keepingspares 5-4when to obtain 5-4recharge date See BatteryRe

Pagina 84

Index 3disabling audio alarm 4-5enabling audio alarm 4-5changing 4-6Low Batteryconfiguration parametersexplained 4-4specifying audio alarm

Pagina 85 - Index 3

4 Compaq 2000 Series UPS Operation and Reference Guidewarranties 1-10Federal CommunicationsCommission (FCC) notice A-1cables A-3FCC Class A co

Pagina 86

Index 5connecting the NetworkTransient Protector 2-5connecting the NetworkTransient Protector,illustrated 2-5connecting to utilitypower 2-7inst

Pagina 87 - Index 5

6 Compaq 2000 Series UPS Operation and Reference Guideexplained 4-4related configurationparameters 4-4nominal utility voltage rangeexplained 4

Pagina 88

Index 7power cordcords shipped with theUPS 2-2requirement for additionalcord 2-3solution for additionalcord 2-3Power Management Software SeeC

Pagina 89 - Index 7

About This Guide ixAny RJ-45 receptacle marked with these symbols indicates a NetworkInterface Connection.WARNING: To reduce the risk of electrical

Pagina 90

8 Compaq 2000 Series UPS Operation and Reference Guideexplained 3-3specificationsbattery C-7battery runtime C-8environmental C-9input C-3o

Pagina 91 - Index 9

Index 9VVCCI Notice for Japan A-5voltage level, nominal,configuring 4-4voltage range, nominal,configuring 4-4Wwarningbattery handling ixelect