Compaq AlphaServer 160 Guía de instalación Pagina 141

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 216
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 140
Create or Update Default.config File 9-3
The default configuration file put in place by the SMC software installation
process is for a single system with multiple consoles. If this system has only one
console line, or if the SMC is being installed to a multi-AlphaServer
configuration, the default.config file will have to be modified.
1. Stop the ConsoleWorks Server.
2. In Windows Explorer go to the folder C:\Cwks\Default\Config. (The files
in this directory are the same as those shown in Figure 9–1 from the
installation disk.)
3. Choose the file appropriate to your configuration (number of AlphaServer
GS80/160/320 systems) and copy it: Files include:
Serial_com1_default.config (1 unpartitioned AlphaServer)
1_ASGS_default.config (1 partionable AlphaServer)
2_ASGS_default.config
.
.
.
32_ASGS_default.config
a. Click on the file to highlight it.
b. From the Edit menu select Copy.
1. Copy of xxxx_default.config is pasted into the folder.
5. Renam the old default.config file to default.config.backup.
6. Rename the file Copy of xxxxxdefault.config to default.config:
a. Click on the file to highlight it.
b. From the File menu select Rename.
c. In the highlighted name enter default.config.
7. Right-click default.config and select properties. Uncheck READ ONLY.
Click OK.
8. Restart the ConsoleWorks Server.
NEXT STEP: For a single SCM, single AlphaServer GS80/160/320, one serial
console line installation, go to Chapter 11. For a single SCM/multiple
AlphaServer GS80/160/320 configuration, go to Chapter 10.