Vista de pagina 0
Compaq Computer Corporation
AlphaServer GS80/160/320
System Management Console
Installation Guide
Order Number: EKGSCON–IN. E01
This manual provides installation and configuration instructions
for the system management console. This manual is for service
providers, managers, and operators of Compaq AlphaServer
GS80/160/320 systems.
Vista de pagina 0
1 2 3 4 5 6 ... 215 216

Indice de contenidos

Pagina 1 - AlphaServer GS80/160/320

Compaq Computer CorporationAlphaServer GS80/160/320System Management ConsoleInstallation GuideOrder Number: EK–GSCON–IN. E01This manual provides insta

Pagina 2

6–1 Cabling Procedure Described in this Chapter ... 6-16–2 GS80/160/320 Keyswitch on New System...

Pagina 3

7-12 SMC Installation Guide7.4 Create New Address and Name for TerminalServer at Remaining SMCGo to the SMC that is to remain in the configuration. Ru

Pagina 4

Consolidating Multi-SMC/AS Configurations to One SMC 7-131. Start Access Server Loader. From the Start menu select Programs|AccessServer Loader|Access

Pagina 5 - Contents

7-14 SMC Installation Guide7.4.2 Add Consolidated Terminal Server Information to theDatabaseAdd the information taken from the SMC being removed to th

Pagina 6

Consolidating Multi-SMC/AS Configurations to One SMC 7-151. The Access Server Loader Configuration dialog box displays (Figure 7–14).On the Clients ta

Pagina 7 - Chapter 8 SMC Definitions

7-16 SMC Installation Guide7.5 Verify the ConnectionReapply power to the terminal server and verify the new connectionthrough the network hub.Figure 7

Pagina 8

Consolidating Multi-SMC/AS Configurations to One SMC 7-17Verify the new terminal server/hub connection.1. Open a Command window: From the Start menu s

Pagina 9

7-18 SMC Installation Guide7.6 Run Access Server Manager to Connect SMC toEach Terminal ServerUse the Access Server Manager to configure the added ter

Pagina 10

Consolidating Multi-SMC/AS Configurations to One SMC 7-191. Start Access Server Manager. From the Start menu select Programs|Access Server Manager|Acc

Pagina 11

7-20 SMC Installation Guide7.6.2 Test the ConnectionFigure 7–18 Access Server Dialog Box, Utilities Tab

Pagina 12

Consolidating Multi-SMC/AS Configurations to One SMC 7-211. In the Access Server dialog box, select the Utilities tab (Figure 7–18). SelectTest Connec

Pagina 13 - Document Structure

xi8–9 Verifying the Network Setup... 8-138–10 Internet Accounts Dialog Box ...

Pagina 14

7-22 SMC Installation Guide7.6.3 Configure Access Server ManagerFigure 7–20 Select a Command File Dialog Box

Pagina 15 - Information on the Internet

Consolidating Multi-SMC/AS Configurations to One SMC 7-231. From the Utilities tab of the Access Server dialog box (Figure 7–18), selectRun Command Fi

Pagina 16

7-24 SMC Installation Guide7.7 Update Configuration: Modify the Default.config FileNow you need to run ConsoleWorks to add consoles and groups to theD

Pagina 17 - Overview and Preparation

Consolidating Multi-SMC/AS Configurations to One SMC 7-251. Start ConsoleWorks from the SMC desktop. The Show Consoles screendisplays.2. At the top of

Pagina 18 - 1-2 SMC Installation Guide

7-26 SMC Installation GuideFigure 7–23 console_name Configuration Screen

Pagina 19 - Software

Consolidating Multi-SMC/AS Configurations to One SMC 7-279. Click the Add Console button. The console_name Configuration screendisplays (Figure 7–23).

Pagina 20 - 1.2 Installation Flow

7-28 SMC Installation Guide7.7.2 Add GroupsFigure 7–24 Add Group Screen1. Start ConsoleWorks from the SMC desktop.2. In the left navigation panel sele

Pagina 21 - Overview and Preparation 1-5

Consolidating Multi-SMC/AS Configurations to One SMC 7-298. Add a console to the group by selecting the checkbox next to the console'sname. Remov

Pagina 22 - 1-6 SMC Installation Guide

7-30 SMC Installation Guide7.8 Cable the Remaining SMC to the CorporateNetworkConnect to the corporate network from network adapter 1 on the SMCsystem

Pagina 23 - MR-0215-01

Consolidating Multi-SMC/AS Configurations to One SMC 7-31Connect a network cable to network adapter 1 on the SMC system, as shown inFigure 7–26. (This

Pagina 24 - Table 1–1 SMC PC Kit

B–1 COM1 Port...B-2B–2 PCI Box Rear – Local Port Connecti

Pagina 28

SMC Definitions 8-1Chapter 8SMC DefinitionsWhen you boot an SMC PC for the first time (see note below for upgrades), theWindows NT4 Operating System a

Pagina 29

8-2 SMC Installation Guide8.1 Set the SMC System Time, Date, and Time ZoneUse the Date/Time icon in the Control Panel to set the time, date, andtime z

Pagina 30

SMC Definitions 8-31. From the Start button, select Settings|Control Panel. The Control Panelwindow displays.2. In the Control Panel double-click the

Pagina 31 - One Console Line

8-4 SMC Installation Guide8.2 Define the SMC’s Network ConnectionsVerify the SMC computer name and the protocol for the private LAN.Specify the SMC IP

Pagina 32 - Figure 2–2 COM1 Port

SMC Definitions 8-51. Open the Windows Control Panel: From the Start menu selectSettings|Control Panel.2. Double-click the Network icon. The Network d

Pagina 33

8-6 SMC Installation Guide8.2.2 Verify the Network ProtocolFigure 8–4 Network Dialog Box

Pagina 34 - Figure 2–4 Network Adapter 1

SMC Definitions 8-71. In the Network dialog box, select the Protocols tab (Figure 8–4). If theprotocol shown is TCP/IP, skip the rest of this page and

Pagina 35

xiiiPrefaceIntended AudienceThis manual is for service providers, managers, and operators of CompaqAlphaServer GS80/160/320 systems.Document Structure

Pagina 36 - 2.3 Check the COM1 Settings

8-8 SMC Installation Guide8.2.3 Define the SMC’s Network Adapter 1Figure 8–6 Microsoft TCP/IP PropertiesNOTE: The IP address values in the illustratio

Pagina 37

SMC Definitions 8-9Enter the static IP address, subnet mask, and gateway. Ask the networkadministrator for this information. The SMC requires a static

Pagina 38

8-10 SMC Installation Guide8.2.4 Define the SMC’s Network Adapter 2Figure 8–7 Microsoft TCP/IP Properties Dialog Box

Pagina 39 - Multiple Serial Console Lines

SMC Definitions 8-111. In the Network dialog box, select the Protocols tab. Click the Propertiesbutton.2. The Microsoft TCP/IP Properties dialog box d

Pagina 40

8-12 SMC Installation Guide8.2.5 Bind the ProtocolFigure 8–8 Bindings Tab in the Network Dialog Box1. In the Network dialog box, select the Bindings t

Pagina 41 - Figure 3–3 Network Adapter 2

SMC Definitions 8-138.2.6 Verify the Network SetupFigure 8–9 Verifying the Network Setup1. Open a Command window: From the Start menu select Programs|

Pagina 42

8-14 SMC Installation Guide8.3 Configure Outlook ExpressObtain mail server information from the network administrator beforeconfiguring.Figure 8–10 In

Pagina 43

SMC Definitions 8-15c. The names of the incoming and outgoing mail servers.5. When Outlook Express sends or receives mail, by default it removes theme

Pagina 45 - 3.2.3 Dress the Cables

Create or Update Default.config File 9-1Chapter 9Create or UpdateDefault.config FileUse this chapter after preliminary SMC setup (Chapter 8). This cha

Pagina 46 - Figure 3–7 Network Adapter 1

xiv• Chapter 6, Adding a System to a Multiple-System Configurationwith One SMC, describes cabling for this situation.• Chapter 7, Consolidating Mult

Pagina 47

9-2 SMC Installation Guide9.1 New Installation: Replace the Default.config FileMake sure the Default.config file is appropriate for the installation.F

Pagina 48

Create or Update Default.config File 9-3The default configuration file put in place by the SMC software installationprocess is for a single system wit

Pagina 49 - MR0216-01

9-4 SMC Installation Guide9.2 Upgrade Configuration: Add Console(s) andGroups(s) to the ConfigurationIf you are upgrading your configuration to includ

Pagina 50 - Off position

Create or Update Default.config File 9-51. Start ConsoleWorks from the SRM Console desktop.2. Select Consoles in the left navigation panel, then Add C

Pagina 51 - GS160/320 power cabinet

9-6 SMC Installation GuideFigure 9–3 console_name Configuration Screen

Pagina 52

Create or Update Default.config File 9-712. Click the Add Console button. The console_name Configuration screendisplays (Figure 9–3).13. Enter the pro

Pagina 53

9-8 SMC Installation Guide9.2.2 Add GroupsFor each AlphaServer system being added to this SCM, you need to useConsoleWorks to add a group and then sel

Pagina 54 - 4.1.3 Record the Connections

Create or Update Default.config File 9-95. Optionally, enter a description.6. Click the Add Group button. The Group group_name screen displays (Figure

Pagina 56 - 4-8 SMC Installation Guide

Run Access Server Software 10-1Chapter 10Run Access Server SoftwareUse this chapter when installing a new SMC to a single, partitionableAlphaServer GS

Pagina 57 - MR0203-01

xvDocumentation TitlesTable 1 AlphaServer GS80/160/320 DocumentationOrder Number TitleQA–6GAAA–G8 AlphaServer GS80/160/320 Documentation KitEK–GS320–U

Pagina 58 - Figure 4–8 Network Adapter 2

10-2 SMC Installation Guide10.1 Run Access Server Loader to Define AddressesThe Access Server Loader configures the IP address and subnet maskof each

Pagina 59

Run Access Server Software 10-31. Start Access Server Loader: From the Start menu select Programs|AccessServer Loader|Access Server Loader. The Access

Pagina 60 - Figure 4–10 Network Adapter 1

10-4 SMC Installation Guide10.1.2 Create the DatabaseFigure 10–3 Access Server Loader Configuration Dialog Box

Pagina 61

Run Access Server Software 10-51. The Access Server Loader Configuration dialog box displays (Figure 10–3).On the Clients tab, enter the following inf

Pagina 62

10-6 SMC Installation Guide10.1.3 Verify Each ConnectionFigure 10–5 Verifying Each Connection

Pagina 63 - Chapter 5

Run Access Server Software 10-7Verify each terminal server connection.1. Open a Command window: From the Start menu selectPrograms|Command Prompt.2. A

Pagina 64

10-8 SMC Installation Guide10.2 Run Access Server Manager to Connect SMC toEach Terminal ServerUse the Access Server Manager to configure each termina

Pagina 65

Run Access Server Software 10-91. Start Access Server Manager. From the Start menu select Programs|Access Server Manager|Access Server Manager. The Ac

Pagina 66

10-10 SMC Installation Guide10.2.2 Test the ConnectionFigure 10–8 Access Server Dialog Box, Utilities Tab

Pagina 67

Run Access Server Software 10-111. In the Access Server dialog box, select the Utilities tab (Figure 10–8). SelectTest Connection. Click the Do It Now

Pagina 69 - 5.1.4 Dress the Cables

10-12 SMC Installation Guide10.2.3 Configure Access Server ManagerFigure 10–10 Select a Command File Dialog Box

Pagina 70 - 2ontheSMC

Run Access Server Software 10-131. From the Utilities tab of the Access Server dialog box (Figure 10–8), selectRun Command File.2. Click the Do It Now

Pagina 72 - 5-10 SMC Installation Guide

Validating Console Groups 11-1Chapter 11Validating Console GroupsIn this chapter, you run the CGValidator program to validate the groups ofconsole lin

Pagina 73

11-2 SCM Installation Guide11.1 Starting CGValidatorStart the CGValidator program and log in; you must be of consolemanager status to be able to log i

Pagina 74 - Figure 5–9 Network Adapter 2

Validating Console Groups 11-31. From the Start menu select Run. When the Run window displays, type thelocation of CGValidator (see Figure 11–1).2. Wh

Pagina 75

11-4 SCM Installation Guide11.2 Review Validated GroupsCGValidator communicates with ConsoleWorks to find all the groupsdefined there and the consoles

Pagina 76 - Figure 5–11 Network Adapter 1

Validating Console Groups 11-5CGValidator examines the groups defined in ConsoleWorks and compares themwith the systems connected to the SMC. It displ

Pagina 77

11-6 SCM Installation Guide11.3 Displaying Data for a GroupWhen you select a group, CGValidator displays data for the systemconnected to that terminal

Pagina 78

Validating Console Groups 11-7In the example in Figure 11–4, the user has selected GS80 for review (shownby dashed lines around the group name).Data f

Pagina 79 - Configuration with One SMC

Overview and Preparation 1-1Chapter 1Overview and PreparationThe system management console, or SMC, is the console device for managingone or more Alph

Pagina 80

11-8 SCM Installation Guide11.4 Disabling a Valid GroupBy unchecking a valid group’s box and clicking “Save GPD”, you candisable a valid group, making

Pagina 81

Validating Console Groups 11-9The user has unchecked the box at GS320; the data for the group is grayed out.By clicking on the “Save GPD” the group is

Pagina 82

11-10 SCM Installation Guide11.5 Invalid GroupsSome console lines may be attached to different AlphaServer systems,making the group not eligible for p

Pagina 83

Validating Console Groups 11-11In Figure 11–7, the user selects a group name that does not have a checkbox.The display is grayed out. Note that it sho

Pagina 84 - 6.1.3 Record the Connections

11-12 SCM Installation Guide11.6 Save All Data to GPDYou save settings for groups made with CGValidator by using the Savebuttons on the screen.Figure

Pagina 85 - 6.1.4 Dress the Cables

Validating Console Groups 11-13Figure 11–8 shows the display after the user has clicked the “Save All” box onthe CGValidator screen. A window is displ

Pagina 87

Configuring the SMC for Remote Use 12-1Chapter 12Configuring the SMC for Remote UseSections in this chapter are:• Set Up the Modem• Configure the Re

Pagina 88

12-2 SMC Installation Guide12.1 Set Up the ModemFollow the manufacturer’s instructions for cabling the modem.Figure 12–1 COM2 PortPK-1735A-00COM2 (B)C

Pagina 89 - Configurations to One SMC

Configuring the SMC for Remote Use 12-32. Open the Control Panel: From the Start menu select Settings|ControlPanel.3. Double-click the Modems icon. Th

Pagina 90

1-2 SMC Installation Guide1.1 System Management Console OverviewThe system management console makes it possible to monitor andcontrol one or more Alph

Pagina 91

12-4 SMC Installation Guide12.2 Configure the Remote Access SoftwareConfigure both remote access applications, Carbon Copy AccessEdition and WinVNC.12

Pagina 92 - Figure 7–4 Network Adapter 2

Configuring the SMC for Remote Use 12-51. Start Carbon Copy Access Edition: From the Start menu selectPrograms|Carbon Copy Access Edition|Carbon Copy.

Pagina 93

12-6 SMC Installation Guide12.2.2 WinVNCFigure 12–5 Default Local System Properties Dialog Box1. Display the WinVNC settings: from the Start menu sele

Pagina 94 - 7-6 SMC Installation Guide

Installing a Terminal Server in a GS160/320 System A-1Appendix AInstalling a Terminal Server in aGS160/320 SystemWhen a GS160/320 system is reconfigur

Pagina 95

A-2 SMC Installation GuideA.1 Remove the Existing Connection from the SMCSystem to the GS160/320Remove the cable between the SMC system and the GS160/

Pagina 96

Installing a Terminal Server in a GS160/320 System A-31. Remove the BN24Q cable (17–04308–05) from the H8585–AA connectors(12–36054–01) on the COM1 po

Pagina 97

A-4 SMC Installation GuideA.2 Attach the Mounting BracketsPosition the top rear holes over the alignment pins. Fasten thebrackets with the M5 screws.F

Pagina 98 - 7-10 SMC Installation Guide

Installing a Terminal Server in a GS160/320 System A-51. Position the holes in the bracket (indicated byin Figure A–3) over thealignment pins () on th

Pagina 99

A-6 SMC Installation GuideA.3 Install the Terminal Server in the GS160/320 PowerCabinetSet the position identifier dial to management agent and instal

Pagina 100 - Server at Remaining SMC

Installing a Terminal Server in a GS160/320 System A-71. Set the position identifier dial at the rear of the terminal server tomanagement agent (the p

Pagina 101

Overview and Preparation 1-3With the system management console (SMC), multiple AlphaServer GS80/160/320 systems with multiple partitions can be manage

Pagina 102 - Database

A-8 SMC Installation GuideA.4 Connect the Terminal Server to the Power SourceConnect the power cord to J19 of the bottom AC input box.Figure A–6 GS160

Pagina 103

Installing a Terminal Server in a GS160/320 System A-9Plug the power cord of the terminal server into J19 of AC input box 1 (thebottom AC input box) i

Pagina 104 - 7.5 Verify the Connection

A-10 SMC Installation GuideA.5 Cable the Terminal Server to the SMC SystemConnect the management channel connector on the terminal server tonetwork ad

Pagina 105

Installing a Terminal Server in a GS160/320 System A-11Figure A–8 Network Adapter 2PK-1723-00MinitowerModel DPENMDesktop BoxModel DPENDMinitower Model

Pagina 106 - Each Terminal Server

A-12 SMC Installation GuideA.6 Cable the Terminal Server to the GS160/320For each console, connect a terminal server port to the local port ofthe PCI

Pagina 107

Installing a Terminal Server in a GS160/320 System A-13Table A–1 Terminal Server CablingQBB NumberTerminal Server PortGS160 GS3201002113224335—46—57—6

Pagina 108 - 7.6.2 Test the Connection

A-14 SMC Installation GuideA.6.2 Record the ConnectionsRecord the connections made for this installation in Table A–2.Table A–2 Terminal Server Cablin

Pagina 109 - Figure 7–19 Telnet Window

Installing a Terminal Server in a GS160/320 System A-15A.6.3 Dress the CableFigure A–11 Terminal Server CablePK-1753-00123456781321. At the PCI box en

Pagina 111

Installing a Terminal Server in a GS80 System B-1Appendix BInstalling a Terminal Server in aGS80 SystemWhen a GS80 system is reconfigured from a singl

Pagina 112 - 7.7.1 Add Consoles

Revised, February 2002© 2002 Compaq Computer Corporation.Compaq, the Compaq logo, Compaq Insight Manager, AlphaServer, StorageWorks, and TruClusterReg

Pagina 113

1-4 SMC Installation Guide1.2 Installation FlowChoose your situation from the choices in Figure 1–3 and follow thesteps listed to install an SMC.Figur

Pagina 114 - 7-26 SMC Installation Guide

B-2 SMC Installation and User's GuideB.1 Remove the Existing Connection from the SMCSystem to the GS80Remove the cable between the SMC system and

Pagina 115

Installing a Terminal Server in a GS80 System B-31. Remove the BN24Q cable (17–04308–05) from the H8585–AA connectors(12–36054–01) on the COM1 port of

Pagina 116 - 7.7.2 Add Groups

B-4 SMC Installation and User's GuideB.2 Attach the Mounting BracketsPosition the top rear holes over the alignment pins. Fasten thebrackets with

Pagina 117

Installing a Terminal Server in a GS80 System B-51. Position the holes in the bracket (indicated byin Figure B–3) over thealignment pins () on the ter

Pagina 118 - Figure 7–26 Network Adapter 1

B-6 SMC Installation and User's GuideB.3 Install the Terminal Server in the GS80 RackSet the position identifier dial to management agent and ins

Pagina 119

Installing a Terminal Server in a GS80 System B-71. Set the position identifier dial at the rear of the terminal server tomanagement agent (the positi

Pagina 120

B-8 SMC Installation and User's GuideB.4 Connect the Terminal Server to the Power SourceConnect the power cord to J5A or J1 of the bottom AC inpu

Pagina 121 - Software Setup

Installing a Terminal Server in a GS80 System B-9Plug the power cord of the terminal server into AC input box 1 (the bottom ACinput box) in the GS80 r

Pagina 122

B-10 SMC Installation and User's GuideB.5 Cable the Terminal Server to the SMC SystemConnect the management channel connector on the terminal ser

Pagina 123 - SMC Definitions

Installing a Terminal Server in a GS80 System B-11Figure B–8 Network Adapter 2PK-1723-00MinitowerModel DPENMDesktop BoxModel DPENDMinitower Model DPEN

Pagina 124 - 8-2 SMC Installation Guide

Overview and Preparation 1-5Figure 1–3 SMC Installation Flowchart (Continued)Ye sYe s Adding AS system to multiple AS systems with 1 S

Pagina 125 - Figure8–2 TimeZoneTab

B-12 SMC Installation and User's GuideB.6 Cable the Terminal Server to the GS80For each console, connect a terminal server port to the local port

Pagina 126 - 8-4 SMC Installation Guide

Installing a Terminal Server in a GS80 System B-13Table B–1 Terminal Server CablingTerminal Server Port QBB Number10213—4—5—6—7—8—Figure B–10 Terminal

Pagina 127

B-14 SMC Installation and User's GuideB.6.2 Record the ConnectionsRecord the connections made for this installation in Table B–2.Table B–2 Termin

Pagina 128 - Figure 8–4 Network Dialog Box

Index-1IndexAAccess Server Loader, 10-2creating the database, 10-4verifying the connection, 10-6Access Server Manager, 7-18, 10-8Telnet window, 7-21,

Pagina 129

Index-2saving data to GPD, 11-12GS80/160/320local port, 2-3, 3-4, 4-4, 5-4, 6-4HH8585–AA connector, 2-3, 3-4, 4-4, 5-4,6-4, A-3, A-12, B-3, B-12Hardwa

Pagina 130 - 8-8 SMC Installation Guide

Index-3network adapter 2, 3-3, A-10setting up the modem, 12-2software, 1-11SoftwareAccess Server, 10-1creating Default.config file, 9-2CGValidator, 11

Pagina 132 - 8-10 SMC Installation Guide

1-6 SMC Installation GuideFigure 1–3 SMC Installation Flowchart (Continued)CEDDMR-0214-01Software Configuration -- Part 2 Define the SMC Network Con

Pagina 133

Overview and Preparation 1-7Figure 1–3 SMC Installation Flowchart (Continued) Adding AS system to one or more AS systems with 1 SMC a

Pagina 134 - 8.2.5 Bind the Protocol

1-8 SMC Installation Guide1.3 Check the Installation KitsThe system management console consists of two or more kits: the SMCPC kit and as many termina

Pagina 135

Overview and Preparation 1-9Appendix A for GS160/320 systems and Appendix B for GS80 systems.) Theorder number for the terminal server kit is 3X–DS8AA

Pagina 136 - 8.3 Configure Outlook Express

1-10 SMC Installation Guide1.4 Set Up the SMCInstall the SMC PC and bring up the operating system. Check theversion of the SMC software and upgrade if

Pagina 137

Overview and Preparation 1-111. Set up the Compaq Deskpro computer and monitor according to theaccompanying instructions.2. Start the SMC system. As t

Pagina 140 - 9-2 SMC Installation Guide

Japanese NoticeCanadian NoticeThis Class A digital apparatus meets all requirements of the Canadian Interference-Causing EquipmentRegulations.Avis Can

Pagina 142 - 9.2.1 Add Consoles

Cabling the SMC to One System with One Console Line 2-1Chapter 2Cabling the SMC to One System withOne Console LineA GS80/160/320 system with a single

Pagina 143

2-2 SMC Installation Guide2.1 Cable the SMC to the GS80/160/320Connect the COM1 port of the SMC system to the local port of theGS80/160/320.Figure 2–2

Pagina 144 - 9-6 SMC Installation Guide

Cabling the SMC to One System with One Console Line 2-3Install H8585–AA connectors (12–36054–01) on the COM1 (or A) port of theSMC system (Figure 2–2)

Pagina 145

2-4 SMC Installation Guide2.2 Cable the SMC to the Corporate NetworkConnect to the corporate network from the network adapter on theSMC system.Figure

Pagina 146 - 9.2.2 Add Groups

Cabling the SMC to One System with One Console Line 2-5Connect a network cable to network adapter 1 on the SMC system, as shown inFigure 2–4. (This ca

Pagina 147

2-6 SMC Installation Guide2.3 Check the COM1 SettingsCheck that the baud rate for the COM1 port is 9600. Change it if it is setto any other speed. Che

Pagina 148

Cabling the SMC to One System with One Console Line 2-71. From the Start button select Settings|Control Panel.2. In the control panel, double-click th

Pagina 150 - 10-2 SMC Installation Guide

Cabling the SMC to One System with Multiple Serial Console Lines 3-1Chapter 3Cabling the SMC to One System withMultiple Serial Console LinesA GS80/160

Pagina 152 - 10.1.2 Create the Database

3-2 SMC Installation Guide3.1 Cable the Terminal Server to the SMCConnect the management channel connector on the terminal server tonetwork adapter 2

Pagina 153 - PK-1783-00

Cabling the SMC to One System with Multiple Serial Console Lines 3-3Figure 3–3 Network Adapter 2PK-1723-00MinitowerModel DPENMDesktop BoxModel DPENDMi

Pagina 154 - 10.1.3 Verify Each Connection

3-4 SMC Installation Guide3.2 Cable the Terminal Server to the GS80/160/320For PCI boxes in an expander cabinet, make the cable connection tothe termi

Pagina 155

Cabling the SMC to One System with Multiple Serial Console Lines 3-5Table 3–1 Terminal Server CablingQBB NumberTerminal ServerPortGS80 GS160 GS3201000

Pagina 156

3-6 SMC Installation Guide3.2.2 Record the ConnectionsRecord the connections made for this installation in Table 3–2.Table 3–2 Terminal Server Cabling

Pagina 157

Cabling the SMC to One System with Multiple Serial Console Lines 3-73.2.3 Dress the CablesForm a service loop and tie wrap the BN25G cable to the rail

Pagina 158 - 10.2.2 Test the Connection

3-8 SMC Installation Guide3.3 Cable the SMC to the Corporate NetworkConnect to the corporate network from network adapter 1 on the SMCsystem.Figure 3–

Pagina 159 - Figure 10–9 Telnet Window

Cabling the SMC to One System with Multiple Serial Console Lines 3-9Connect a network cable to network adapter 1 on the SMC system, as shown inFigure

Pagina 161

Cabling an SMC to a Multi-System Configuration 4-1Chapter 4Cabling an SMC to a Multi-SystemConfigurationYou can control multiple AlphaServer systems f

Pagina 162

vContentsPreface...xiiiChapter 1 Overview and

Pagina 163 - Validating Console Groups

4-2 SMC Installation Guide4.1 Cable Each AS System to a Terminal ServerThis installation requires a new DECsystem 90 Terminal Server foreach system an

Pagina 164 - 11.1 Starting CGValidator

Cabling an SMC to a Multi-System Configuration 4-3Check that the keyswitch on the each GS80/160/320 system is turned to Off (asshown in Figure 4–2). T

Pagina 165

4-4 SMC Installation Guide4.1.2 Cable Each AS System to Terminal ServerCable the local port of each PCI box with a standard I/O module in agiven syste

Pagina 166 - 11.2 Review Validated Groups

Cabling an SMC to a Multi-System Configuration 4-5Table 4–1 Terminal Server CablingQBB NumberTerminal ServerPortGS80 GS160 GS320100021113—224—335——46—

Pagina 167

4-6 SMC Installation Guide4.1.3 Record the ConnectionsRecord the connections made for this installation in Table 4–2.Table 4–2 Terminal Server Cabling

Pagina 168 - 11-6 SCM Installation Guide

Cabling an SMC to a Multi-System Configuration 4-74.1.4 Dress the CablesForm a service loop and tie wrap the BN25G cable to the rail.Figure 4–5 Termin

Pagina 169

4-8 SMC Installation Guide4.2 Cable All Terminal Servers to Network HubCable all the terminal servers to the network hub.Figure 4–6 Terminal Server Ma

Pagina 170 - 11.4 Disabling a Valid Group

Cabling an SMC to a Multi-System Configuration 4-9Figure 4–7 Ports on an 8-port Network Hub...LEDsElectrical outletPort 2Port 18Front view Rear viewMR

Pagina 171

4-10 SMC Installation Guide4.3 Connect the Network Hub to the SMCConnect the network hub to network adapter 2 on the SMC.Figure 4–8 Network Adapter 2P

Pagina 172 - 11.5 Invalid Groups

Cabling an SMC to a Multi-System Configuration 4-111. Connect the appropriate cable (as defined by the instructions that comewith the network hub, not

Pagina 173

4.3 Connect the Network Hub to the SMC ... 4-104.4 Cable the SMC to the Corporate Network...

Pagina 174 - 11.6 Save All Data to GPD

4-12 SMC Installation Guide4.4 Cable the SMC to the Corporate NetworkConnect to the corporate network from network adapter 1 on the SMCsystem.Figure 4

Pagina 175

Cabling an SMC to a Multi-System Configuration 4-13Connect a network cable to network adapter 1 on the SMC system, as shown inFigure 4–10. (This cable

Pagina 177 - Chapter 12

Adding an AS System to Single AS System with SMC Already Installed 5-1Chapter 5Adding an AS System to Single ASSystem with SMC Already InstalledYou ca

Pagina 178 - 12.1 Set Up the Modem

5-2 SMC Installation Guide5.1 Cable New AS System to New Terminal ServerThis installation requires a new DECsystem 90 Terminal Server and anew network

Pagina 179 - Figure 12–2 Modem Detected

Adding an AS System to Single AS System with SMC Already Installed 5-3Check that the keyswitch on the new GS80/160/320 system is turned to Off (asshow

Pagina 180 - Edition and WinVNC

5-4 SMC Installation Guide5.1.2 Cable New AS System to New Terminal ServerCable the local port of each PCI box with a standard I/O module in thenew sy

Pagina 181

Adding an AS System to Single AS System with SMC Already Installed 5-5Table 5–1 Terminal Server CablingQBB NumberTerminal ServerPortGS80 GS160 GS32010

Pagina 182 - 12.2.2 WinVNC

5-6 SMC Installation Guide5.1.3 Record the ConnectionsRecord the connections made for this installation in Table 5–2.Table 5–2 Terminal Server Cabling

Pagina 183 - GS160/320 System

Adding an AS System to Single AS System with SMC Already Installed 5-75.1.4 Dress the CablesForm a service loop and tie wrap the BN25G cable to the ra

Pagina 184 - System to the GS160/320

viiTerminal Server ... 7-187.6.1 Open Access Server Manager ...

Pagina 185 - PK-1724-00

5-8 SMC Installation Guide5.2 Disconnect Cable from Old Terminal Server toSMCDisconnect the cable from the old terminal server to the SMC.Figure 5–6 D

Pagina 186 - Figure A–3 Mounting Brackets

Adding an AS System to Single AS System with SMC Already Installed 5-9Disconnect the SMC from the old terminal server.NOTE: You do not need to power d

Pagina 187

5-10 SMC Installation Guide5.3 Cable New and Old Terminal Servers to NetworkHubCable both the new and old terminal servers to the network hub.Figure 5

Pagina 188 - A-6 SMC Installation Guide

Adding an AS System to Single AS System with SMC Already Installed 5-11Figure 5–8 Ports on an 8-port Network Hub...LEDsElectrical outletPort 2Port 18F

Pagina 189 - PK-1740-00

5-12 SMC Installation Guide5.4 Connect the Network Hub to the SMCConnect the network hub to network adapter 2 on the SMC.Figure 5–9 Network Adapter 2P

Pagina 190 - A-8 SMC Installation Guide

Adding an AS System to Single AS System with SMC Already Installed 5-131. Connect appropriate cable (as defined by the instructions that come withthe

Pagina 191

5-14 SMC Installation Guide5.5 Cable the SMC to the Corporate NetworkConnect to the corporate network from network adapter 1 on the SMCsystem.Figure 5

Pagina 192 - PK-1769-00

Adding an AS System to Single AS System with SMC Already Installed 5-15Connect a network cable to network adapter 1 on the SMC system, as shown inFigu

Pagina 194

Adding a System to a Multiple-System Configuration with One SMC 6-1Chapter 6Adding a System to a Multiple-SystemConfiguration with One SMCYou can cont

Pagina 195 - PK-1770A-00

Chapter 11 Validating Console Groups11.1 Starting CGValidator... 11-211.2 Revie

Pagina 196 - A.6.2 Record the Connections

6-2 SMC Installation Guide6.1 Cable New AS System to New Terminal ServerThis installation requires a new DECsystem 90 Terminal Server and anetwork hub

Pagina 197 - A.6.3 Dress the Cable

Adding a System to a Multiple-System Configuration with One SMC 6-3Check that the keyswitch on the new GS80/160/320 system is turned to Off (asshown i

Pagina 198

6-4 SMC Installation Guide6.1.2 Cable New AS System to New Terminal ServerCable the local port of each PCI box with a standard I/O module in thenew sy

Pagina 199 - GS80 System

Adding a System to a Multiple-System Configuration with One SMC 6-5Table 6–1 Terminal Server CablingQBB NumberTerminal ServerPortGS80 GS160 GS32010002

Pagina 200 - System to the GS80

6-6 SMC Installation Guide6.1.3 Record the ConnectionsRecord the connections made for this installation in Table 6–2.Table 6–2 Terminal Server Cabling

Pagina 201

Adding a System to a Multiple-System Configuration with One SMC 6-76.1.4 Dress the CablesForm a service loop and tie wrap the BN25G cable to the rail.

Pagina 202 - Figure B–3 Mounting Brackets

6-8 SMC Installation Guide6.2 Cable New Terminal Server to Network HubCable the new terminal server to the network hub.Figure 6–6 Terminal Server Mana

Pagina 203

Adding a System to a Multiple-System Configuration with One SMC 6-9Figure 6–7 Ports on an 8-port Network Hub...LEDsElectrical outletPort 2Port 18Front

Pagina 205 - PK-1791-00

Consolidating Multi-SMC/AS Configurations to One SMC 7-1Chapter 7Consolidating Multi-SMC/ASConfigurations to One SMCYou can consolidate a multi-AS con

Pagina 206 - Figure B–6 GS80 AC Input Box

ixFigures1–1 Components of the System Management Console (SMC)... 1-11–2 SMC in Multi-System Configuration...

Pagina 207

7-2 SMC Installation Guide7.1 Choose the SMC to Remain and Add HubPick the SMC to remain in the configuration (usually the one with themost connection

Pagina 208

Consolidating Multi-SMC/AS Configurations to One SMC 7-31. From the configurations, select an SMC to serve as the single SMC in thenew configuration.

Pagina 209 - Figure B–8 Network Adapter 2

7-4 SMC Installation Guide7.1.2 Connect the Network Hub to the Chosen SMCConnect the network hub to network adapter 2 on the SMC chosen toremain in th

Pagina 210

Consolidating Multi-SMC/AS Configurations to One SMC 7-51. Connect appropriate cable (as defined by the instructions that come withthe network hub, no

Pagina 211 - PK-1770-00

7-6 SMC Installation Guide7.2 Copy Information from SMCs to Be RemovedWhile each SMC is still running, copy the information from each SMCto be removed

Pagina 212 - B.6.2 Record the Connections

Consolidating Multi-SMC/AS Configurations to One SMC 7-71. From the START task button, select Programs| Access Server Manager.When the Browser window

Pagina 213 - GPD, 11-7

7-8 SMC Installation GuideFigure 7–8 Copy Console Information5. Copy information for each console, as shown in Figure 7–8, including thename (likely t

Pagina 214

Consolidating Multi-SMC/AS Configurations to One SMC 7-97. Copy the hardware address label for the terminal server (see in Figure7–9).8. Disconnect th

Pagina 215

7-10 SMC Installation Guide7.3 Cable Terminal Server to the Network HubCable the terminal server being transferred to the network hub.Figure 7–10 Term

Pagina 216

Consolidating Multi-SMC/AS Configurations to One SMC 7-111. Cable the terminal server being transferred to the network hub. Connectone end of a BN25G

Comentarios a estos manuales

Sin comentarios