Compaq HSG80 - StorageWorks RAID Array Controller Especificaciones Pagina 312

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 396
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 311
7–116
CLI Commands
Due to the amount of information being passed from one controller to the other, this
command may take up to one minute to complete.
Example
This example shows how to configure two controllers to operate in dual-redundant
mode within a multiple bus environment:
SET THIS_CONTROLLER ID=(0,1,2,3)
RESTART THIS_CONTROLLER
SET MULTIBUS_FAILOVER COPY=THIS_CONTROLLER
The configuration on “this controller” is automatically copied to the “other
controller” when you issue the SET MULTIBUS_FAILOVER COPY command. If
you want to prefer specific units to specific controllers, use the following command
after setting multiple bus failover:
SET D100 PREFERRED=THIS_CONTROLLER
SET D101 PREFERRED=OTHER_CONTROLLER
See also
SET FAILOVER
SET NOFAILOVER
SET NOMULTIBUS_FAILOVER
Vista de pagina 311
1 2 ... 307 308 309 310 311 312 313 314 315 316 317 ... 395 396

Comentarios a estos manuales

Sin comentarios