Compaq HSG80 - StorageWorks RAID Array Controller Especificaciones Pagina 58

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 396
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 57
2–14
Controller and Host Concepts
Table 2–3 shows the cache policies resulting from full or partial failure of cache
module As ECB in a dual-redundant configuration. Note that when cache module A
is at least 50% charged, the ECB is still operable and charging. When it is less than
50% charged, the ECB is low but still charging. The consequences shown in this table
are opposite for a failure of cache module B’s ECB.
Cache
Board
Failure
Good Same as for DIMM failure. Data integrity: Controller A
recovers all of its write-back data
from the mirrored copy on
cache B.
Cache policy: Both controllers
support write-through caching
only. Controller B cannot execute
mirrored writes because cache
module A cannot mirror
controller B’s unwritten data.
Failover: No
Table 2–2. Cache Policies and Cache Module Status (Continued)
Cache Module Status Cache Policy
Cache A Cache B Unmirrored Cache Mirrored Cache
Vista de pagina 57
1 2 ... 53 54 55 56 57 58 59 60 61 62 63 ... 395 396

Comentarios a estos manuales

Sin comentarios