Compaq HSG80 - StorageWorks RAID Array Controller Especificaciones Pagina 43

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 396
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 42
1–19
Compaq HSG80 Array Controller ACS Version 8.4 Configuration and CLI Reference Guide
Battery Hysteresis
When charging a battery, write-back caching will be allowed as long as a previous
down time has not drained more than 50 percent of a battery’s capacity. When a
battery is operating below 50 percent capacity, the battery is considered to be low, and
write-back caching is disabled.
CAUTION: Compaq recommends that you replace the ECB every two
years to prevent battery failure.
NOTE: If a UPS is used for backup power, the controller does not check the battery.
See “SET controller,” page 7–91 for information about the CACHE_UPS and
NOCACHE_UPS switches.
Vista de pagina 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 ... 395 396

Comentarios a estos manuales

Sin comentarios