ProLiant DL380 Generation 2 Server
Maintenance and Service Guide
Second Edition (June 2001)
Part Number 203840-002
Spare Part Number 228520-001
Compaq Computer Corporation
Vista de pagina 0
1 2 3 4 5 6 ... 120 121

Indice de contenidos

Pagina 1 - Compaq Computer Corporation

ProLiant DL380 Generation 2 ServerMaintenance and Service GuideSecond Edition (June 2001)Part Number 203840-002Spare Part Number 228520-001Compaq Comp

Pagina 2

Illustrated Parts Catalog 1-3System Components11161479151019782317121322182021Figure 1-2. System componentsNOTE: Items not shown in the illustrati

Pagina 3 - Contents

Connectors, LED Indicators, Switches, and Jumpers 4-21JumpersThe ProLiant DL380 Generation 2 server contains one two-pin bootblock flash jumper. Ite

Pagina 4 - Chapter 4

Chapter 5SpecificationsThis chapter provides operating and performance specifications for ProLiant DL380Generation 2 server components and hardware, i

Pagina 5 - Chapter 5

5-2 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideSystem UnitTable 5-1Operating and Performance Specifications for theProLi

Pagina 6 - About This Guide

Specifications 5-3Hot-Plug Power SupplyTable 5-2Hot-Plug Power Supply SpecificationsItem DescriptionInput voltage specificationsRated input voltage

Pagina 7

5-4 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service Guide1.44-MB Diskette DriveTable 5-41.44-MB Diskette DriveItem DescriptionSize

Pagina 8 - Illustrated Parts Catalog

Specifications 5-5CD-ROM DriveTable 5-5CD-ROM Drive SpecificationsItem DescriptionApplicable disk CD-ROM (modes 1 and 2); mixed mode (audio and data

Pagina 9 - Mechanical Components

5-6 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideWide Ultra3 SCSI Hard DrivesTable 5-6Wide Ultra3 SCSI Hard Drive Specific

Pagina 10 - System Components

IndexAAC power connected LED 4-8access panelairflow concerns 2-3, 2-14installing 2-15part number 1-2removing 2-14replacing 2-15spare part

Pagina 11 - Table 1-2

2 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service Guidepower button/LED See powerbutton/LED boardsystem See system boardbootbl

Pagina 12

Index 3Compaq Insight Manager XEaccess 3-2description 3-2Compaq Integration MaintenanceUtility 3-3Compaq Management CD 3-3Compaq ProLiant DL

Pagina 13 - Safety Considerations

1-4 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideTable 1-2System Components Spare Parts List continuedItem Description Par

Pagina 14 - Rack Warnings and Cautions

4 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service Guidepower button/LED cable 2-43,2-59power cables 2-41power cords 2-3, 2-5

Pagina 15 - Preparation Procedures

Index 5removing 2-24replacing 2-24screws 2-24spare part number 1-2front fan bracketinstalling 2-30part number 1-3removing 2-30replacin

Pagina 16

6 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service Guidereplacing 2-12spare part number 1-3specifications 5-3hot-plug SCSI ha

Pagina 17 - Powering Down the Server

Index 7Kkeyboard connector 4-2kitscountrypart number 1-5spare part number 1-5hardwarecontents 1-5spare part number 1-5miscellaneous cablec

Pagina 18 - Hot-Plug Procedures

8 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service Guidemechanical components 1-2memory See also DIMMsconfiguration 2-44insta

Pagina 19 - Hot-Plug SCSI Hard Drive

Index 9miscellaneous cable kit 1-4PCI expansion boardejector/divider 1-5PCI riser cage 1-3plastics kit 1-5power button/LED board 1-4power

Pagina 20 - Hard Drive Blank

10 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service Guidepower supply signal 2-41SCSI power 2-41system power 2-41power connec

Pagina 21 - CD Blank

Index 11rated input power 5-2rated input voltage 5-2rated steady-state power 5-2RBSU See ROM-Based SetupUtilityrear fan bracketinstalling

Pagina 22 - Universal Hot-Plug Tape Drive

12 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service Guidefans, hot-plug 2-16front bezel 2-24front fan bracket 2-30hard drive

Pagina 23 - Tape Drive Blank

Index 13populating bays 2-7, 2-8removing 2-7replacing 2-7SCSI IDs 2-7specifications 5-6SCSI IDs 2-7SCSI interlock disable switchdefault

Pagina 24

Illustrated Parts Catalog 1-5Table 1-2System Components Spare Parts List continuedItem Description Part Number Spare Part NumberMiscellaneous28 Hard

Pagina 25 - Power Supply Blank

14 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuidespecificationsCD-ROM drive 5-5DIMMs 5-3diskette drive 5-4hot-plug po

Pagina 26 - Access Panel

Index 15expansion slot 1 2-34, 2-35front panel 2-4PCI riser cage 2-32power converter module 2-42SCSI backplane 2-31system board 2-30, 2-

Pagina 27

Chapter 2Removal and Replacement ProceduresThis chapter provides subassembly/module-level removal and replacement procedures forProLiant DL380 Generat

Pagina 28 - Hot-Plug Fan

2-2 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideSymbols on Equipment25 kg55 lbAny product or assembly marked with these s

Pagina 29 - Air Baffle

Removal and Replacement Procedures 2-3CAUTION: Always begin by mounting the heaviest item on the bottom of the rack. Continue topopulate the rack f

Pagina 30 - PCI Shipping Bracket

2-4 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideExtending the Server from the RackTo extend the server from the rack: 1.

Pagina 31 - PCI Riser Cage Door Latch

Removal and Replacement Procedures 2-5Powering Down the ServerSystem power in ProLiant DL380 Generation 2 servers does not completely shut off with

Pagina 32

2-6 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service Guide 5. At the rear of the server, locate the illuminated rear unit identifi

Pagina 33

Removal and Replacement Procedures 2-7 For hot-plug drive procedures, determine whether the drive is part of an array. For moreinformation, refer

Pagina 34

Notice© 2001 Compaq Computer CorporationCompaq, the Compaq logo, Compaq Insight Manager, ProLiant, ROMPaq, and SmartStart Registered inU.S. Patent and

Pagina 35

2-8 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideHard Drive BlankTo remove a hard drive blank: 1. Press the release butto

Pagina 36 - Non-Hot-Plug Procedures

Removal and Replacement Procedures 2-9CD BlankTo remove the CD blank: 1. Push the ejection button . 2. Pull the CD blank out the CD MultiBay .12

Pagina 37

2-10 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideUniversal Hot-Plug Tape DriveTo remove a universal hot-plug tape drive:

Pagina 38 - Diskette Drive

Removal and Replacement Procedures 2-11Tape Drive BlankTo remove the tape drive blank: 1. Remove the hot-plug SCSI hard drive or hard drive blank i

Pagina 39 - CD MultiBay Adapter Board

2-12 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideHot-Plug Power SupplyCAUTION: Do not attempt to remove and replace a po

Pagina 40 - CD Ejector Assembly

Removal and Replacement Procedures 2-13Power Supply BlankTo remove the power supply blank: 1. Unlock the hinge on the cable arm and swing the arm a

Pagina 41

2-14 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideAccess PanelCAUTION: Do not operate the server for extended periods wit

Pagina 42 - Front Fan Bracket

Removal and Replacement Procedures 2-15 4. Slide the access panel toward the rear of the unit about 1.25 cm (0.5 inch) and lift toremove the panel.

Pagina 43 - SCSI Backplane

2-16 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideHot-Plug FanCAUTION: Do not attempt to remove and replace a fan as a ho

Pagina 44 - PCI Riser Cage

Removal and Replacement Procedures 2-17Air BaffleTo remove the air baffle: 1. Extend or remove the server from the rack. See the “Preparation Proce

Pagina 45 - 8. Lift the PCI riser cage

ContentsAbout This GuideSymbols in Text...viiCom

Pagina 46 - Expansion Board (Slot 1)

2-18 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuidePCI Shipping BracketTo remove the PCI shipping bracket: 1. Extend or re

Pagina 47 - Expansion Slot Cover (Slot 1)

Removal and Replacement Procedures 2-19PCI Riser Cage Door LatchTo remove the PCI riser cage door latch: 1. Extend or remove the server from the ra

Pagina 48

2-20 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideReverse steps 1 through 5 to replace the PCI riser cage door latch.Expan

Pagina 49

Removal and Replacement Procedures 2-21 5. Press the PCI Hot Plug button for five seconds to power down the slot.2Figure 2-19. Pressing the PCI Ho

Pagina 50

2-22 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideCAUTION: Always install either an expansion board or an expansion slot

Pagina 51 - PCI Lightpipe and Cover

Removal and Replacement Procedures 2-23 4. Press the PCI slot release lever to unlock it . 5. Open the PCI slot release lever . 6. Slide the ex

Pagina 52

2-24 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideNon-Hot-Plug ProceduresYou must power down the ProLiant DL380 Generation

Pagina 53 - Power Converter Module

Removal and Replacement Procedures 2-25CD-ROM DriveTo eject the CD-ROM drive: 1. Power down the server. See the “Powering Down the Server” section

Pagina 54

2-26 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideDiskette DriveTo remove a diskette drive: 1. Power down the server. See

Pagina 55 - Power Button/LED Board

Removal and Replacement Procedures 2-27CD MultiBay Adapter BoardTo remove the CD MultiBay adapter board: 1. Power down the server. See the “Powerin

Pagina 56

iv Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideRemoval and Replacement ProcedurescontinuedNon-Hot-Plug Procedures ...

Pagina 57 - Processors

2-28 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideCD Ejector AssemblyTo remove the CD ejector assembly: 1. Power down the

Pagina 58 - 10. Remove the processor

Removal and Replacement Procedures 2-29 9. Use a Torx T-15 screwdriver to remove the ejector assembly screw . 10. Press and hold the ejection but

Pagina 59 - 2. Insert the processor

2-30 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideFront Fan BracketTo remove the front fan bracket: 1. Power down the ser

Pagina 60

Removal and Replacement Procedures 2-31SCSI BackplaneTo remove the SCSI backplane: 1. Power down the server. See the “Powering Down the Server” sec

Pagina 61 - Figure 2-49. Removing a PPM

2-32 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuidePCI Riser CageCAUTION: To avoid the risk of damage to your system or ex

Pagina 62 - Smart Array 5i Controller

Removal and Replacement Procedures 2-33 8. Lift the PCI riser cage.Figure 2-32. Removing the PCI riser cageReverse steps 1 through 7 to replace th

Pagina 63

2-34 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideExpansion Board (Slot 1)To remove an expansion board from slot 1: 1. Po

Pagina 64 - 5. Remove the battery

Removal and Replacement Procedures 2-35Expansion Slot Cover (Slot 1)To remove an expansion slot cover from slot 1: 1. Power down the server. See th

Pagina 65 - System Board

2-36 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuidePCI Expansion Board Ejector/DividerTo remove the expansion board ejector

Pagina 66

Removal and Replacement Procedures 2-37PCI Slot Release Lever (Slots 2 and 3)To remove a PCI slot release lever: 1. Power down the server. See the

Pagina 67

Contents vConnectors, LED Indicators, Switches, and JumperscontinuedSystem Switches...

Pagina 68 - Rear Fan Bracket

2-38 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service Guide 8. From the rear of the PCI riser cage, press the slot release lever t

Pagina 69 - SCSI Cable (Short)

Removal and Replacement Procedures 2-39PCI Lightpipe and CoverTo remove the PCI lightpipe and cover: 1. Power down the server. See the “Powering Do

Pagina 70 - CD MultiBay Cable

2-40 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service Guide 7. Slide the lightpipe out of the chassis.Figure 2-39. Sliding the li

Pagina 71 - Power Button/LED Cable

Removal and Replacement Procedures 2-41Power Converter ModuleTo remove the power converter module: 1. Power down the server. See the “Powering Down

Pagina 72 - System Cables

2-42 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service Guide 8. Loosen the thumbscrew that secures the power converter module to th

Pagina 73 - PCI Hot Plug Backplane Cable

Removal and Replacement Procedures 2-43Power Button/LED BoardTo remove the power button/LED board: 1. Power down the server. See the “Powering Down

Pagina 74

2-44 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideDIMMsTo remove DIMMs: 1. Power down the server. See the “Powering Down

Pagina 75 - Optional SCSI Cable (Long)

Removal and Replacement Procedures 2-45ProcessorsTo remove a processor: 1. Power down the server. See the “Powering Down the Server” section in thi

Pagina 76 - Diagnostic Tools

2-46 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service Guide 8. Remove the heatsink .CAUTION: Discard the heatsink after you remo

Pagina 77 - Table 3-1

Removal and Replacement Procedures 2-47 2. Insert the processor . 3. Close the locking lever on the processor socket .12Figure 2-46. Installing

Pagina 78 - Diagnostic Tools 3-3

About This GuideThis maintenance and service guide is a troubleshooting guide that can be used for referencewhen servicing the Compaq ProLiant DL380 G

Pagina 79

2-48 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service Guide 5. Install the heatsink . 6. Carefully install the heatsink-retainin

Pagina 80

Removal and Replacement Procedures 2-49PPMsTo remove a PPM: 1. Power down the server. See the “Powering Down the Server” section in this chapter. 2

Pagina 81 - Connectors

2-50 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideSmart Array 5i ControllerTo remove the Smart Array 5i Controller: 1. Po

Pagina 82 - System Board Connectors

Removal and Replacement Procedures 2-51BatteryIf the server no longer automatically displays the correct date and time, you may need to replacethe b

Pagina 83 - LED Indicators

2-52 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service Guide 5. Remove the battery.Figure 2-51. Removing the batteryReverse steps

Pagina 84 - Front Panel LEDs

Removal and Replacement Procedures 2-53System BoardTo remove the system board: 1. Power down the server. See the “Powering Down the Server” section

Pagina 85 - Hot-Plug SCSI Hard Drive LEDs

2-54 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service Guide 14. Loosen the system board thumbscrew.Figure 2-52. Loosening the sys

Pagina 86 - Table 4-4

Removal and Replacement Procedures 2-55 16. Slide the system board toward the front of the server and lift the system board off thealignment keys.F

Pagina 87 - PCI Riser Cage LEDs

2-56 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideRear Fan BracketTo remove the rear fan bracket: 1. Power down the serve

Pagina 88 - PCI Hot Plug LEDs

Removal and Replacement Procedures 2-57SCSI Cable (Short)To remove the short SCSI cable: 1. Power down the server. See the “Powering Down the Serve

Pagina 89 - RJ-45 Network Connector LEDs

viii Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideWARNING: To reduce the risk of personal injury from electrical shock an

Pagina 90

2-58 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideCD MultiBay CableTo remove the CD MultiBay cable: 1. Power down the ser

Pagina 91 - Hot-Plug Power Supply LED

Removal and Replacement Procedures 2-59Power Button/LED CableTo remove the power button/LED cable: 1. Power down the server. See the “Powering Down

Pagina 92 - Hot-Plug Fan LED

2-60 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideSystem CablesTo remove the LED/CD-ROM drive system cable or the diskette

Pagina 93 - System Board LEDs

Removal and Replacement Procedures 2-61PCI Hot Plug Backplane CableTo remove the PCI Hot Plug backplane cable: 1. Power down the server. See the “P

Pagina 94 - Table 4-8

2-62 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideOptional Remote Insight Lights-Out Edition Interface CableTo remove the

Pagina 95 - Table 4-9

Removal and Replacement Procedures 2-63Optional SCSI Cable (Long)To remove the long SCSI cable: 1. Power down the server. See the “Powering Down th

Pagina 96

Chapter 3Diagnostic ToolsThis chapter is an overview of software and firmware diagnostic tools that are available forconfiguring, monitoring, and mana

Pagina 97 - System Switches

3-2 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideUse the following tools to diagnose problems, test hardware, and monitor

Pagina 98 - NMI Switch

Diagnostic Tools 3-3Table 3-1Diagnostic Tools continuedTool Description How to run the toolCompaq SmartStart for Servers Compaq SmartStart software

Pagina 99 - Chassis ID Switch

3-4 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideTable 3-1Diagnostic Tools continuedTool Description How to run the toolRO

Pagina 100

Chapter 1Illustrated Parts CatalogThis chapter provides the illustrated parts breakdown and spare parts list for theCompaq ProLiant™ DL380 Generation

Pagina 101 - Specifications

Chapter 4Connectors, LED Indicators, Switches,and JumpersThis chapter explains the location and function of system connectors, internal and externalLE

Pagina 102 - System Unit

4-2 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideConnectorsThe figures and tables on the following pages show connector lo

Pagina 103 - Hot-Plug Power Supply

Connectors, LED Indicators, Switches, and Jumpers 4-3System Board ConnectorsFigure 4-2 and Table 4-2 show the connectors on the system board.6578910

Pagina 104 - 1.44-MB Diskette Drive

4-4 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideLED IndicatorsThe ProLiant DL380 Generation 2 server contains several set

Pagina 105 - CD-ROM Drive

Connectors, LED Indicators, Switches, and Jumpers 4-5Front Panel LEDsThe five LEDs on the front of the server indicate server status. Figure 4-3 and

Pagina 106 - Wide Ultra3 SCSI Hard Drives

4-6 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideThe internal health LED identifies service events for internal components

Pagina 107

Connectors, LED Indicators, Switches, and Jumpers 4-7Table 4-4Hot-Plug SCSI Hard Drive LED Status Combinations Activity Online FaultMeansOn Off Of

Pagina 108

4-8 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuidePCI Riser Cage LEDsThe PCI riser cage contains two LEDs. The slot speed L

Pagina 109

Connectors, LED Indicators, Switches, and Jumpers 4-9PCI Hot Plug LEDsThe PCI Hot Plug LEDs adjacent to each expansion slot provide a visual referen

Pagina 110

4-10 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideRJ-45 Network Connector LEDsThe RJ-45 network connector on the server re

Pagina 111

1-2 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideMechanical Components165243Figure 1-1. Mechanical componentsTable 1-1Mec

Pagina 112

Connectors, LED Indicators, Switches, and Jumpers 4-11Rear Unit Identification LED SwitchThe rear unit identification LED switch offers a visual ref

Pagina 113

4-12 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideHot-Plug Power Supply LEDDetermine the hot-plug power supply status by o

Pagina 114

Connectors, LED Indicators, Switches, and Jumpers 4-13Hot-Plug Fan LEDEach of the hot-plug fans contains a dual-color LED (Figure 4-10).Figure 4-10.

Pagina 115

4-14 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuidePower Converter Module LEDThe power converter module LED indicates wheth

Pagina 116

Connectors, LED Indicators, Switches, and Jumpers 4-1510 1134567892112Figure 4-12. System board LEDsTable 4-8System Board LEDsItem LED Description

Pagina 117

4-16 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideSystem LEDs and Internal Health LED Status CombinationsWhen the internal

Pagina 118

Connectors, LED Indicators, Switches, and Jumpers 4-17Table 4-9System LEDs and Internal Health LED Status Combinations continuedSystem LED and Color

Pagina 119

4-18 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideSystem SwitchesWith system switches, you can enable or disable certain s

Pagina 120

Connectors, LED Indicators, Switches, and Jumpers 4-19SCSI Interlock Disable SwitchThe SCSI interlock disable switch (Figure 4-13) is a two-position

Pagina 121

4-20 Compaq ProLiant DL380 Generation 2 Server Maintenance and Service GuideSystem Maintenance SwitchThe system maintenance switch is a six-position