4-1 Troubleshooting
Compaq ProLiant Storage System /U User Guide
Chapter 4
Troubleshooting
This chapter contains troubleshooting procedures and suggestions that should
be followed to diagnose problems quickly and minimize the impact on system
operation.
Using the Status Indicators
If the fault indicator on the front panel is amber, or if Compaq Insight Manager
indicates a fault, immediately determine the reason for this alert. Examine the
component status indicators to see if any of them are indicating a fault.
Disk Drives
Look for an amber Drive Failure indicator on any hot-pluggable drive tray.
TROJ018.EPS
Drive Failure Indicator
Figure 4-1. Drive Failure indicator
If any Drive Failure indicator is amber, replace that drive as soon as possible.
See “Replacing Components” later in this chapter for important information on
when it is safe to replace drives. Failure to observe these instructions can result
in loss of data.