Compaq StorageWorks 6000 - Virtual Library System Guía de usuario Pagina 282

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 358
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 281
2. Slide the power supply into the bay until it clicks.
Figure 95 Installing a node power supply
.
3. Connect the power cord to the power supply.
4. Be sure that the power supply LED is green.
5. Be sure that the front panel external health LED is green.
Fan
CAUTION:
Do not operate the node for long periods without the access panel. Operating the node without the
access panel results in improper airflow and improper cooling that can lead to thermal damage.
NOTE:
The server supports variable fan speeds. The fans operate at minimum speed until a temperature
change requires a fan speed increase to cool the server.
The server shuts down in the following scenarios:
At POST:
The BIOS suspends the server for 5 minutes if it detects a cautionary temperature level. If the
cautionary temperature level is still detected after 5 minutes, the BIOS performs an orderly
shutdown and enters Standby mode.
The BIOS performs an orderly shutdown if two or more fans have failed.
The server performs an immediate shutdown if it detects a critical temperature level.
IMPORTANT:
An immediate shutdown is a hardware-controlled function and it overrides any firmware or
software actions.
Component Replacement282
Vista de pagina 281
1 2 ... 277 278 279 280 281 282 283 284 285 286 287 ... 357 358

Comentarios a estos manuales

Sin comentarios