Compaq 4354R - StorageWorks Enclosure Storage Manual de servicio Pagina 30

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 218
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 29
1–6 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide
Units are divided between the host ports:
Units 0-99 are on host port 1 of both controllers (but accessible only through the active
port).
Units 100-199 are on host port 2 of both controllers (but accessible only through the
active port).
Transparent failover only compensates for a controller failure, and not for failures of either
the Fibre Channel link or host Fibre Channel adapters.
Figure 1–5. Transparent failovernormal operation
CXO7036A
Host
port 1
active
Host
port 2
active
D100 D101 D120D0 D1
Host 1
Switch or hub
Host 2
Switch or hub
Host 3
Controller A
Controller B
Host
port 2
standby
Host
port 1
standby
Vista de pagina 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 217 218

Comentarios a estos manuales

Sin comentarios