Compaq 4354R - StorageWorks Enclosure Storage Manual de servicio Pagina 32

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 218
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 31
1–8 HSG80 ACS Solution Software Version 8.6 for Compaq Tru64 UNIX Installation and Configuration Guide
In multiple-bus failover mode, you can specify which units are normally serviced by a
specific controller of a controller pair. This process is called preferring or preferment.
Units can be preferred to one controller or the other by the PREFERRED_PATH switch of
the
ADD UNIT (or SET unit) command. For example, use the following command to prefer unit
D101 to “this controller”:
SET D101 PREFERRED_PATH=THIS_CONTROLLER
NOTE: This is an initial preference, which can be overridden by the hosts.
Keep the following points in mind when configuring controllers for multiple-bus failover:
Multiple-bus failover can compensate for a failure in any of the following:
Controller
Switch or hub
Fibre Channel link
Host Fibre Channel adapter
A host can redistribute the I/O load between the controllers
All hosts must have operating system software that supports multiple-bus failover
mode
Vista de pagina 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 217 218

Comentarios a estos manuales

Sin comentarios