Planning a Subsystem 1–9
Figure 1–7. Typical multiple-bus configuration
Selecting a Cache Mode
The cache module supports read, read-ahead, write-through, and write-back caching
techniques. The cache technique is selected separately for each unit. For example, you can
enable only read and write-through caching for some units while enabling only write-back
caching for other units.
CXO7094B
Host
port 1
active
Host
port 2
active
Host
port 2
active
Host
port 1
active
D100 D101 D120D0 D1 D2
Host 1
"RED"
Controller A
Controller B
All units visible to all ports
FCA1 FCA2
Host 2
"GREY"
FCA1 FCA2
Host 3
"BLUE"
FCA1 FCA2
Switch
or hub
Switch
or hub
NOTE: FCA = Fibre Channel Adapter