Vista de pagina 114
6-33
Compaq Smart Array 3200 Controller Reference Guide
Writer: Rickard Project: Compaq Smart Array 3200 Controller Reference Guide Comments: 340862-002
File Name: G-CH06.DOC Last Saved On: 12/7/98 9:23 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Installing the Driver
To install the driver file to the OS/2 directory on your boot drive:
1. Place the OS/2 SSD diskettes in the floppy drive.
2. From the OS/2 command prompt, change the drive to A: by typing:
a:
Then type:
Ddinstal
3. Click the Change button to change the source directory to A:/ADD.
4. Select Compaq Array Driver for OS/2 from the list of drivers. Click OK
to continue.
5. The CPQARRAY.ADD driver file will be copied to the x:\os2 directory
(where x is the boot drive). The CONFIG.SYS file will be updated to load
this driver first on boot. This means that the first drive on this controller
is the boot drive.
6. If you do not want to boot from a drive on this controller–for instance, if
you wanted to boot from a drive attached to the integrated SCSI
controller–you must manually change the CONFIG.SYS file before you
reboot the server. Edit the CONFIG.SYS file to reorder the
BASEDEV=CPQARRAY.ADD statement so that it appears after the
BASEDEV statement corresponding to the boot driver.
7. Save the updated CONFIG.SYS file and exit the editor.
8. Perform a normal system shutdown and reboot the server to load the new
driver.
Vista de pagina 114
1 2 ... 110 111 112 113 114 115 116 117 118 119 120 ... 210 211

Comentarios a estos manuales

Sin comentarios