Compaq 3200 Especificaciones Pagina 31

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 211
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 30
2-11
Compaq Smart Array 3200 Controller Reference Guide
Writer: Rickard Project: Compaq Smart Array 3200 Controller Reference Guide Comments: 340862-002
File Name: C-CH02.DOC Last Saved On: 12/7/98 8:33 AM
COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED
Controller 1 Controller 2
ID5 ID5
ID4 ID4
ID3 d ID3
ID2 c ID2 z
ID1 b Array A ID1 y Array A
ID0 a ID0 x
Figure 2-5. Failed arrays removed; arrays on separate controllers
To restore an array to its original controller, make sure the conditions for
moving drives are met. Then:
IMPORTANT: These steps must be followed AS DESCRIBED. Any deviation
or mistake could result in the loss of all data across all moved arrays.
1. Power-down the system.
2. Move the array back to its original controller but retain its drive position
from the consolidated configuration.
3. Power-up the system.
4. Each controller will indicate a 1789 POST message, “Drives are
Missing.” Press F2 to fail the missing drives.
5. Run the Array Configuration Utility and remove the appropriate failed
arrays.
6. Reboot the system.
Vista de pagina 30
1 2 ... 26 27 28 29 30 31 32 33 34 35 36 ... 210 211

Comentarios a estos manuales

Sin comentarios