B-6 POST Error Messages
POST Error Messages Continued
Screen Message Beeps* Probable Cause Recommended Action
1720-SMART Hard Drive
Detects Imminent Failure
None Hard drive is about to fail.
(Some hard drives have a
firmware patch that will fix
an erroneous error
message.)
1. Determine if hard drive is
giving correct error message.
Run the Drive Protection
System test available.
2. Apply firmware patch if
applicable.
3. Back up contents and replace
hard drive.
1721-SMART SCSI Hard
Drive Detects Imminent
Failure
None Hard drive is about to fail.
(Some hard drives have a
firmware patch that will fix
an erroneous error
message.)
1. Determine if hard drive is
giving correct error message.
Run the Drive Protection
System test available.
2. Apply firmware patch if
applicable.
3. Back up contents and replace
hard drive.
1771-Primary Disk Port
Address Assignment
Conflict
2S Internal and external hard
drive controllers are both
assigned to the primary
address.
1. Remove any Comm port
expansion cards.
2. Clear CMOS.
3. Reconfigure card resources
and/or run Computer Setup
(F10 Setup).
1772-Secondary Disk Port
Address Assignment
Conflict
2S Internal and external hard
drive controllers are both
assigned to the primary
address.
1. Remove any Comm port
expansion cards.
2. Clear CMOS.
3. Reconfigure card resources
and/or run Computer Setup
(F10 Setup).
1780-Disk 0 Failure None Hard drive/format error. 1. Run Computer Setup (F10
Setup).
2. Clear CMOS.
3. Check cables/jumper settings.
4. Run hard drive diagnostics.
5. Disconnect additional drives.
6. Run the Drive Protection
System test if available.
7. Replace the hard drive.
* L = Long, S = Short
continued