3.3.3 Futurebus+ PIU
Only supported on DEC7000/10000 systems.
The Futurebus+ PIU houses a Futurebus+ card cage and regulators. It occupies 1 (lower,
rear) PIU quadrant. A maximum of 2 per cabinet and 3 per system is allowed (1 XMI must
be present).
The Futurebus backplane has 10 slots. Slot 5 contains the FLAG module, leaving 9 slots
for I/O.
See Section 5 for a discussion of the Futurebus+ itself.
3.3.4 SCSI Disk and Tape PIU
Only supported on DEC7000/10000 systems.
The SCSI disk and tape PIU houses any combination of 3.5" disk and tape drives and 5.25"
disk drives. It occupies 1 (any) PIU quadrant. A maximum of 2 in the system cabinet and
4 in the expander is allowed.
This PIU contains 2 vertical sections (called shelves!) Each shelf has 7 slots for disks or
tapes. 3.5" devices, RZ26-VA or TLZ06-VA, use 1 slot. 5.25" devices, RZ73-VA, use 3 slots.
To satisfy airflow requirements, the PIU is mounted upside-down if fitted in the top of an
expander cabinet.
3.3.5 DSSI Disk PIU
The DSSI disk PIU houses 1 to 3 disk "bricks". Each brick contains 2 x 5.25" disks (EG:
RF73). It occupies 1 (any) PIU quadrant. A maximum of 2 in the system cabinet and 4 in
the expander is allowed. To satisfy airflow requirements, disk bricks are installed starting
closest to the blower and working down (or up). Also, the PIU is mounted upside-down if
fitted in the top of an expander cabinet.
3.3.6 Battery PIU
The battery PIU houses 1 to 3 battery blocks. Each block contains 4 x 12v batteries. 1
block is required for each 48v regulator. This PIU requires 2 (lower) PIU quadrants due
to it’s size and weight. A maximum of 1 per cabinet is allowed. If the 48v regulators are
reconfigured for phase balancing (see Section 3.1.3, Power ), then the batteries must also be
reconfigured. See Platform Service Manual for more details.
The batteries are used as a UPS rather than BBU. They supply power to everything in the
cabinet and provide ’ride-through’ for short duration power outages. On a fully configured
7000 system they provide a UPS for 10 minutes. On a 10000 system special half-width
battery cabinets are supplied, containing sufficient battery PIUs to provide a UPS for 1
hour.