Remote Management Console 3-3
Figure 32 Location of RMC Components on Motherboard - DS10L
PK2204
1
RMC PIC
Processor
RMC
Jumper
1
Halt/Reset
Jumper
The RMC logic is implemented using an 8-bit microprocessor, PIC17C44, as the
primary control device. The RMC PIC is programmed with code to control
access to various environmental status bits.
You can gain access to the RMC as long as AC power is available to the system
(through the wall outlet). Thus, if the system fails, you can still access the RMC
and gather information about the failure. The RMC jumper position shown in
Figure 3–1 and Figure 3–2 is the default position set in manufacturing which
enables the RMC. To disable RMC, move the jumper to cover the middle pin
and the other end pin.