3-10 DS10 / DS10L Console Reference
3.6 Status Monitoring
Use the RMC status command to check the current state of the
system’s sensors as well as the current escape sequence and
alarm information.
RMC> sta
PLATFORM STATUS
Firmware Revision: V1.1
Power: ON
RMC Halt: Deasserted
RMC Power Control: ON
Power Supply: OK
System Fans: OK CPU Fan: OK
Temperature: 31.0°C (warnings at 55.0°C, power-off at 60.0°C)
Escape Sequence: ^[^[RMC
Remote Access: Disabled
RMC Password: set
Alert Enable: Disabled
Alert Pending: YES
Init String: AT&F0E0V0S0=2
Dial String: ATXDT8,18007598888
Alert String: ,,,,,,,1066278#,,,,,,,,1#,,,,30140#;
Com1_mode: SNOOP
Last Alert: AC Loss
Watchdog Timer: 00 seconds
Autoreboot: OFF
Logout Timer: 20 minutes
User String:
Table 32 Status Command Fields
Field Meaning
Firmware Revision
Revision of RMC firmware on the microcontroller.
Power
On = System is on.
Off = System is off.
RMC Halt
Asserted = System has been halted by RMC.
Deasserted = Halt has been released by RMC.
Continued on next page.