10-6 DS20E Reference Guide
Compaq Confidential – Need to Know Required
Writer: Robert Young Project: AlphaServer DS20E System Comments:
Part Number: ER-K8F6W-UA .A01 File Name: k-ch10 Managing the System Remotely.doc Last Saved On: 10/4/99 1:33 PM
Using RMC Locally or with a Modem on COM1
Use the default escape sequence to invoke the RMC mode locally for the first
time. You can invoke RMC from the SRM console, the operating system, or
an application. The RMC quit command reconnects the terminal to the system
console port.
1. To invoke the RMC locally, type the RMC escape sequence. See ➊ in
Example 10-3 for the default sequence.
The escape sequence is not echoed on the terminal or sent to the system.
At the RMC> prompt, you can enter RMC commands.
2. To exit RMC and reconnect to the system console port, enter the quit
command (see
➋). Press Return to get a prompt from the operating
system or system console.
P00>>> ^]^]RMC ➊
RMC>
RMC> quit
➋
Focus returned to COM port
Example 10-3. Invoking and Leaving RMC Locally
Comentarios a estos manuales