P00>>> show power
Status
Power Supply 0 good
Power Supply 1/Fan Tray good
System Fans good
CPU Fans good
Temperature good
Current ambient temperature is 27 degrees C
System shutdown temperature is set to 55 degrees C
2 Environmental events are logged in nvram
Do you want to view the events? (Y/<N>) y
Total Environmental Events: 2 (2 logged)
1 000 0 0:00 Temperature, Fans, Power Supplies Normal
2 000 0 0:00 Temperature, Fans, Power Supplies Normal
Do you want to clear all events from nvram? (Y/<N>) y
P00>>>
Example 11-6. Show Power Command
The show power command displays status information about the power
supplies, system fans, CPU fans, and temperature. This command is useful for
displaying the error state of a Tru64 UNIX or OpenVMS system that shuts
down because of a fan, temperature, or power supply failure. If the system can
be restarted, use this command. (If it cannot, use the RMC status command.
See Chapter 6.)