4–24 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
■●●❍●❍●
35 An unexpected bugcheck occurred during
Last Failure processing.
Last Failure Processing interrupted by
another Last Failure event.
Reset controller.
■●●❍●●❍
36 Hardware-induced controller reset
expected.
Automatic hardware reset failed.
Replace controller.
■●●❍●●●
37 Software-induced controller reset
expected.
Software-induced reset failed.
Replace controller.
■●●●❍❍❍
38 Controller operation terminated.
Last Failure event required termination of
controller operation (e.g. SHUT DOWN VIA
CLI).
Reset controller.
■●●●❍❍●
39 NVPM configuration inconsistent.
Device configuration within the NVPM is
inconsistent.
Replace controller.
■●●●❍●❍
3A An unexpected NMI occurred during Last
Failure processing.
Last Failure processing interrupted by a
Non-Maskable Interrupt (NMI).
Replace controller.
■●●●❍●●
3B NVPM read loop hang.
Attempt to read data from NVPM failed.
Replace controller.
■●●●●❍❍
3C NVPM write loop hang.
Attempt to write data to NVPM failed.
Replace controller.
■●●●●❍●
3D NVPM structure revision greater than
image’s.
NVPM structure revision number is
greater than the one that can be handled
by the software version attempting to be
executed.
Replace program card with one that
contains the latest software version.
Table 4–5 Solid OCP Patterns (Sheet 4 of 5)