Compaq HSG80 - StorageWorks RAID Array Controller Especificaciones Pagina 88

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 296
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 87
3–4 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
2. Load the image onto a PC or workstation using its file- or network-transfer
capabilities.
3. From a host console, quiesce all port activity and dismount the storage units in the
subsystem.
IMPORTANT: Do not remove the program card in the next step.
4. Remove the program card ESD cover.
If the program card is equipped with a write-protection switch (as shown in
Figure 3–2), disable write-protection by sliding the switch to the “write” position.
Figure 3–2. Location of write-protection switch
5. Connect a PC or terminal to the controller maintenance port.
6. Start CLCP with the following command:
RUN CLCP
The following menu appears:
Select an option from the following list:
Code Load & Patch local program Main Menu
0: Exit
1: Enter Code LOAD local program
2: Enter Code PATCH local program
3: Enter EMU Code LOAD Utility
Enter option number (0..3) [0] ?
Write
Write
protected
CXO5873B
1
2
Vista de pagina 87
1 2 ... 83 84 85 86 87 88 89 90 91 92 93 ... 295 296

Comentarios a estos manuales

Sin comentarios