Compaq HSG80 - StorageWorks RAID Array Controller Especificaciones Pagina 156

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 296
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 155
4–50 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
DILX
Checking for Disk Drive Problems
Use DILX to check the data-transfer capability of disk drives. DILX generates intense
read/write loads to the disk drive while monitoring drive performance and status. Run
DILX on as many disk drives as desired, but since this utility creates substantial I/O loads
on the controller, Compaq recommends stopping host-based I/O during the test.
IMPORTANT: DILX cannot be run on remote copy sets (ACS V8.5P only).
Finding a Disk Drive in the Subsystem
Use the following steps to find a disk drive or device in the subsystem:
1. Connect a PC or a terminal to the controller maintenance port.
2. Show the devices that are configured on the controller with the following command:
SHOW DEVICES
3. Find the device in the enclosure with the following command:
LOCATE
device-name
This command causes the device LED to blink continuously.
4. Enter the following command to turn off the LED:
LOCATE CANCEL
Testing the Read Capability of a Disk Drive
Use the following steps to test the read capability of a disk drive:
1. From a host console, dismount the logical unit that contains the disk drive being tested.
2. Connect a terminal to the controller maintenance port that accesses the disk drive
being tested.
3. Run DILX with the following command:
RUN DILX