Compaq HSG80 - StorageWorks RAID Array Controller Especificaciones Pagina 215

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 296
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 214
Event Reporting: Templates and Codes 5–51
018F2087 A NMI interrupt was generated with an indication that a controller system problem occurred.
Last Failure Parameter [0] contains the value of read diagnostic register 0.
Last Failure Parameter [1] contains the value of read diagnostic register 1.
Last Failure Parameter [2] contains PCI status. Bits 31::24 hold PCFX PSCR status and
bits 15::08 hold PLX PSCR status.
Last Failure Parameter [3] contains the PCFX PDAL control/status register.
Last Failure Parameter [4] contains the IBUS address of error register.
Last Failure Parameter [5] contains the previous PDAL address of error register.
Last Failure Parameter [6] contains the current PDAL address of error register.
20
01902086 The PCI bus on the controller will not allow a master to initiate a transfer. Unable to provide
further diagnosis of the problem.
Last Failure Parameter [0] contains the value of read diagnostic register 0.
Last Failure Parameter [1] contains the value of read diagnostic register 1.
Last Failure Parameter [2] contains the value of read diagnostic register 2.
Last Failure Parameter [3] contains the value of write diagnostic register 0.
Last Failure Parameter [4] contains the value of write diagnostic register 1.
Last Failure Parameter [5] contains the IBUS address of error register.
20
01910084 A Cache Module was inserted or removed.
Last Failure Parameter [0] contains the value of actual Cache Module A exists state.
Last Failure Parameter [1] contains the value of actual Cache Module B exists state.
Last Failure Parameter [2] contains the value of expected Cache Module A exists state.
Last Failure Parameter [3] contains the value of expected Cache Module B exists state.
00
01920186 Unable to read the FX because a Device Port or a Host Port locked the PDAL bus.
Last Failure Parameter [0] contains the value of read diagnostic register 0.
Last Failure Parameter [1] contains the value of read diagnostic register 1.
Last Failure Parameter [2] contains the value of read diagnostic register 2.
Last Failure Parameter [3] contains the value of write diagnostic register 0.
Last Failure Parameter [4] contains the value of write diagnostic register 1.
Last Failure Parameter [5] contains the IBUS address of error register.
01
Table 5–18 Last Failure Codes (Sheet 5 of 41)
Code Description
Repair
Action
Code
Vista de pagina 214