Vista de pagina 53
2–26 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
6. Enter option 1. The following menu appears:
Replace or remove Options:
1. Other controller and cache module
2. Other controller module
3. Other cache module
4. Exit
Enter choice: 1, 2, 3, or 4 ->
7. Enter option 2. The following display appears:
Slot Designations
(front view)
[ --- EMU --- ][ --- PVA --- ]
[ -------- Controller A ------- ]
[ -------- Controller B ------- ]
[ Cache Module A ][ Cache Module B ]
Remove the slot A [
or B
] controller? Y/N
8. Type Y(es). The following display appears:
Quiescing all device ports. Please wait...
Device Port 1 quiesced.
Device Port 2 quiesced.
Device Port 3 quiesced.
Device Port 4 quiesced.
Device Port 5 quiesced.
Device Port 6 quiesced.
All device ports quiesced.
Remove the slot A [
or B
] controller (the one without a blinking green
LED) within 2 minutes.
CAUTION: The device ports must quiesce before removing the controller. Failure to
allow the ports to quiesce might result in data loss. Quiescing might take several
minutes.
ESD can easily damage a controller. Wear a snug-fitting, grounded ESD wrist strap.