Vista de pagina 215
5–52 Compaq StorageWorks HSG80 Array Controller ACS Version 8.5 Maintenance and Service Guide
01932588
01942088
An error has occurred on the
CDAL
.
Last Failure Parameter [0] contains the value of read diagnostic register 0.
Last Failure Parameter [1] contains the value of read diagnostic register 1.
Last Failure Parameter [2] contains the value of write diagnostic register 0.
Last Failure Parameter [3] contains the value of write diagnostic register 1.
Last Failure Parameter [4] contains the IBUS address of error register.
Last Failure Parameter [5] contains the PCFX
CDAL
control / status register.
Last Failure Parameter [6] contains the previous
CDAL
address of error register.
Last Failure Parameter [7] contains the current
CDAL
address of error register.
Applies to
PDAL
.
25
20
01950188 An error has occurred that caused the FX to be rest, when not permissible.
Last Failure Parameter [0] contains the value of read diagnostic register 0.
Last Failure Parameter [1] contains the value of read diagnostic register 1.
Last Failure Parameter [2] contains the value of write diagnostic register 0.
Last Failure Parameter [3] contains the value of write diagnostic register 1.
Last Failure Parameter [4] contains the IBUS address of error register.
Last Failure Parameter [5] contains the PCFX PDAL control / status register.
Last Failure Parameter [6] contains the PCFX CDAL control / status register.
Last Failure Parameter [7] contains the current PDAL address of error register.
01
01960186 The Ibus is inaccessible.
Last Failure Parameter [0] contains the value of read diagnostic register 0.
Last Failure Parameter [1] contains the value of read diagnostic register 1.
Last Failure Parameter [2] contains the value of read diagnostic register 2.
Last Failure Parameter [3] contains the value of write diagnostic register 0.
Last Failure Parameter [4] contains the value of write diagnostic register 1.
Last Failure Parameter [5] contains the IBUS address of error register.
01
Table 5–18 Last Failure Codes (Sheet 6 of 41)
Code Description
Repair
Action
Code