Event Reporting: Templates and Codes 5–3
Table 5–2 Template 01—Last Failure Event Sense Data Response Format
offset bit 76543210
0 Unused Error Code
1Unused
2 Unused Sense Key
3–6 Unused
7 Additional Sense Length
8–11 Unused
12 Additional Sense Code (ASC)
13 Additional Sense Code Qualifier (ASCQ)
14 Unused
15–17 Unused
18–31 Reserved
32–35 Instance Code
36 Template
37 Template Flags
38–53 Reserved
54–69 Controller Board Serial Number
70–73 Controller Software Revision Level
74 Reserved or Patch Version (TM2)
75 Reserved
76 LUN Status
77–103 Reserved
104–107 Last Failure Code
108–111 Last Failure Parameter [0]
112–115 Last Failure Parameter [1]
116–119 Last Failure Parameter [2]
120–123 Last Failure Parameter [3]
124–127 Last Failure Parameter [4]
128–131 Last Failure Parameter [5]
132–135 Last Failure Parameter [6]
136–139 Last Failure Parameter [7]